BATTERY CARE AND MAINTENANCE (CONT.)
HOW TO CHARGE BATTERIES
WARNING:
Explosive gases can arise while
charging. Avoid sparks and open flames.
Verify that there is adequate ventilation
while charging. The charger should not
be used in the vicinity of flammable gases.
Avoid chargers with plastic casing coming into contact
with oils, grease, etc., as most types of plastic can be
broken down by chemicals and solvents.
UBC-24 BATT. CHARGER
Part Number .....................10167
BAT-01
UBC-24
From AC
Battery
Under
Test
SPECIFICATIONS
Input Rating:
Nominal
90-264VAC/47-
63Hz
Maximum Output
Power:
60W
Input Connection:
3 pin IEC 320
(input cordset not
included)
Output
Connection:
Battery clips
Dimensions/
Weight:
5.31” x 3.15” x 1.73”
(135 x 80 x 44mm)/
0.77 lbs. (350g)
1. The charger and battery should be placed in a well-
ventilated area during charging.
2. Do not connect the charger to the socket before it is
connected to the battery.
3. Verify that the polarity is correct and connect the
charger cable: Red to red; black to black (use provided
adapter for lithium batteries).
4. Connect the charger to the socket.
5. When charging is finished, do not leave battery on
charger for an extended period of time. Disconnect
the charger from the socket before you disconnect the
charger from the battery.
LEDS INDICATE FOLLOWING CHARGE STATUS:
CONSTANT CURRENT MODE
• The charger is in constant current mode. LEDs change to
red.
• Charge current is at its maximum.
TIMED CONSTANT MODE
• The charger is in constant voltage mode. LEDs change
to orange.
• Charge current is less than its maximum.
• The battery is normally 80-95% charged.
• The charger stays in this mode until the charge current
decreases to charge termination level.
FINAL MODE
• The battery is fully charged. The LED changes to green.
• Remove battery from charger.
LITHIUM BATTERY ADAPTER
The provided lithium battery adapter
must be used with the UBC Charger to
charge lithium batteries.
USER’S GUIDE
13
2018