background image

23

RECOMMENDED REPLACEMENT PARTS

For spare and/or replacement parts, please contact the Smith & Loveless, Inc. Parts Depart-

ment at

 (800) 922-9048

.  

All of the parts furnished by SMITH & LOVELESS, 

INC. in the 

SONIC START

®

 Retrofit Kit (“Retrofit 

Kit”) are warranted to be free from defects in 

materials  and  workmanship  for  five  years  (5 

years) based on a prorated warranty from date 

of shipment. 

During the warranty period, if any part in the 

Retrofit  Kit  is  defective  or  fails  to  perform  as 

specified when operating at design conditions 

and if the Retrofit Kit has been installed, and 

the  pump  station  operated  and  maintained, 

in  accordance  with  the  written  instructions 

provided  by  SMITH  &  LOVELESS,  SMITH 

& LOVELESS will repair or exchange, at our 

discretion, such defective part free of charge. 

Defective Retrofit Kit parts must be returned by 

Owner postage paid to SMITH & LOVELESS, if 

so requested.  If requested to return a Retrofit 

Kit part, a Returned Goods Authorization sticker 

will be sent to Owner and must be affixed to 

the outside of the shipping container with the 

number  plainly  visible.  Labor  and  any  other 

expense  to  remove  and  install  replacement 

Retrofit Kit parts are the responsibility of Owner. 

SMITH  &  LOVELESS  will  not  assume 

WARRANTY

Part #  

Description

4L628F 

Sonic Start

®

Sensor

4L264S 

Sonic Start

®

 Operating Module

1L545A-2 

DIN Connector Cable

5L49B  

8 Pin Socket

5L57C  

Cord Grip

5L150A 

Cable Ties

1L545A  

Solenoid Valve

87B133B 

Dome

Part #  

Description

87A384 

Brass Bulkhead Adapter

11L4J  

O-Ring for Bulkhead Adapter

6L222A 

Jam Nut

1L43B  

Reducer Coupling

1L460D 

Male Tubing Connector

5L57C-2 

O-Ring for Cord Grip

5L57C-1 

Nut for Cord Grip

11L4K  

O-Ring for Dome

responsibility  for  the  cost  of  any  repairs  or 

alterations  made  to  the  Retrofit  Kit  unless 

SMITH & LOVELESS has given specific written 

authority to do so.

This Limited Warranty does not cover parts dam-

aged by acts of vandalism, God or intentional 

misuse by the owner. 

SMITH & LOVELESS makes no other warranty, 

expressed  or  implied  and  SPECIFICALLY 

DISCLAIMS  ANY  IMPLIED  WARRANTY 

AS  TO  THE  MERCHANTABILITY  OF  THE 

CHECK  VALVE  PUMP  FAILURE  ALARM 

RETROFIT KIT OR AS TO ITS FITNESS FOR 

ANY  PARTICULAR  PURPOSE.    SMITH  & 

LOVELESS is not responsible for consequential 

or incidental damages of any nature resulting 

from such things as, but not limited to, defects 

in design, material, workmanship, or delays in 

delivery, replacements, or repairs. 

The waiver or abridgment of any single provision 

or  group  of  provisions,  either  by  ruling  or 

agreement, shall not be construed to alter or 

void any other provisions of this Warranty.

Summary of Contents for SONIC START STREAMLINE H87A457

Page 1: ...E H87A457 H87A459 Installation Operation Instructions Smith Loveless Inc Thank you for purchasing the Smith Loveless Inc patented Sonic Start StreamlineTM Retrofit Kit S L Part No H87A457 H87A459 This...

Page 2: ...t avoided could result in death or serious injury These signs appear with an orange background and black letters CAUTION Indicates a potentially hazardous situation which if not avoided may result in...

Page 3: ...1L142BC Tubing 19 1 87P31 Installation Instructions This Document not shown PARTS INCLUDED IN KIT Please make sure your kit contains all of the parts and quantities noted in the Item and Description...

Page 4: ...conditions monitored during this procedure to prevent overflow Depending upon the flow conditions of the pump station it may be necessary to pump the wet well down to the off level float Some pump sta...

Page 5: ...dome assembly Item 1 This will make it easy to install the dome into the motor adapter or adapter ring Now install the dome into the motor adapter or adapter ring NOTE Motor adapter ring shown see Ph...

Page 6: ...Photo 5 C Install the vacuum release ball valve Item 6 onto the close nipple Item 5 see Photo 6 D Wrap the threads of the pipe plug Item 7 with Teflon tape and install onto the other end of the vacuum...

Page 7: ...ds of the close nipple Item 5 and install into the open port of the street tee item 8 see Photo 11 F Install the ball valve Item 6 onto the close nipple Item 5 see Photo 12 G Wrap the threads of the p...

Page 8: ...o the control panel and there is no delay timer on the solenoid valve most stations from 2002 2008 see Diagram 2 If you have this option go to step 9 Option 3 Solenoid valve is mounted off the vacuum...

Page 9: ...t to the motor conduit with cable ties Item 10 see Photo 16 If a higher enclosure rating must be maintained or if you want a separate cord grip for the DIN connector cable item 9 put a 3 4 hole in the...

Page 10: ...the solenoid valve is wired to the black wire of the delay timer Typically this is located in the wire troughs see Photo 19 Connect the red wire of the DIN connector cable Item 9 to the black wire of...

Page 11: ...t all neutral and ground wires are still tied together properly see Photo 23 Go to step 11 Photo 22 Photo 23 Diagram 4 Option 1 After Step 9 OPTION 2 This is only for stations with the solenoid valve...

Page 12: ...p OR The DIN connector cable item 9 can be run through an existing panel hole if the enclosure is NEMA 1 rated If you elect to do it this way a new hole in the control panel does not need to be drille...

Page 13: ...on the panel through the mounting hole on the timer see Photo 29 Drill a hole with a 20 drill bit at the punch mark Screw the self tapping screw Item 15 into the new hole to secure the timer to the p...

Page 14: ...cable Item 9 to neutral see Photo 35 and connect the white wire to ground see Photo 36 Diagram 5 shows a typical updated wiring schematic with the delay timer Item 14 added Remove the old solenoid va...

Page 15: ...self tapping screw Item 15 into the new hole to secure the delay timer Item 14 to the panel see Photo 40 The delay timer Item 14 will be installed inline directly before the solenoid valve Run a wire...

Page 16: ...44 and connect the white wire to ground see Photo 45 Use a screwdriver to disconnect the DIN connector on the existing solenoid valve Connect the new or existing DIN connector cable Item 9 to the new...

Page 17: ...If there is not enough space to install the piping assembly Item 17 the shut off valve and or tee may be removed from the assembly see Photo 49 Step 12 Connect the vacuum tubing Item 18 to the quick d...

Page 18: ...n the Sonic Start Streamline Vacuum Priming System Step 16 Perform a final check to make sure everything is complete Check that all vacuum tubing Item 18 is in place and secure in the fittings see Pho...

Page 19: ...s primed Electrical Problems Indicating Light A flashing Red light means that there is an overload or short circuit in the SONIC START wiring or a problem with the SONIC START Prime Sensing Probe See...

Page 20: ...n 3 If tightening does not fix the leak take the connection that is leaking apart and put Teflon tape or other thread sealant on the male fitting and reassemble 4 Check the reeds in the vacuum pump If...

Page 21: ...f this still does not solve the problem then switch out the SONIC START Prim Sensing Probe itself The Troubleshooting 3 If the pump runs but it is not primed and the Green indicating light is On and t...

Page 22: ...es not correct the flashing Red light then check the Din Connector Cable Item 9 Make sure the Din Connector Cable Item 9 is securely screwed in and attached to the SONIC START Prime Sensing Probe If i...

Page 23: ...Owner SMITH LOVELESS will not assume WARRANTY Part Description 4L628F Sonic Start Sensor 4L264S Sonic Start Operating Module 1L545A 2 DIN Connector Cable 5L49B 8 Pin Socket 5L57C Cord Grip 5L150A Cab...

Page 24: ...Loveless Inc 14040 Santa Fe Trail Drive Lenexa KS 66215 1284 USA Ph 800 922 9048 Fax 913 748 0106 www smithandloveless com E mail answers smithandloveless com Part 87P31 Smith Loveless Inc 2003 2009 0...