Step 13:
Run the vacuum tubing
(Item 18)
over to
the top of the
Sonic Start® Streamline™
Vacuum Dome Assembly
(Item 1) (see
Photo 52).
If your vacuum pumps are located under
the control panel, make sure there is an
arc in the tubing
(Item 18)
between the
dome and vacuum pump
(see Photo 52)
Step 14:
Trim the vacuum tubing
(Item 18)
to length
so there are no large sags, but do leave a
little bit of slack
(see Photo 52)
.
Step 15:
Remove any remaining vacuum tubing
from the previous sytem that is not being
used in the
Sonic Start® Streamline™
Vacuum Priming System
.
Step 16:
Perform a final check to make sure
everything is complete.
Check that all vacuum tubing
(Item 18)
is in place and secure
in the fittings
(see Photo 53)
.
Check that the dome assembly
(Item 1)
is secure and restrained
in the pump adapter
(see Photo
54)
.
Check that all tools and unused
parts are removed from the
station.
Step 17:
Turn on the power and confirm that
the operation of the
SONIC START
®
Streamline
TM
Prime Sensing System
is fully functional for this pump before
making any changes to other pumps.
Photo 54
11
Photo 53
20
P h o t o 5 2
1
18
Step 18:
Once the proper operation is confirmed
return to Step 1 if there are additional
pumps to upgrade.