background image

Installation

16

U.S. Installation only / 3-wire branch 
circuit

Refer to figure, where local codes allow the 
connection of the ground wire from the 
oven to the power supply cable neutral 
wire (white wire):
•  The ground wire must be connected first;
•  If local codes permit, connect the green 

or yellow-green ground wire from the 
range and the white wire from the range 
to the power supply neutral wire (white 
wire).

•  Connect the red and black leads from 

the range to the matching color wires in 
the junction box using UL/CSA listed 
wire connectors.

U.S. and Canada installation / 4-wire 
branch circuit

•  Separate the green or yellow-green 

wires from the white wires that extend out 
of the end of the appliance cable.

•  The ground wire must be connected first.
•  Connect the green or yellow-green 

ground wire from the appliance to the 
ground wire in the junction box (green 
colored wire) using UL/CSA listed wire 
connectors. Do not connect the 
grounding wire to the neutral wire in the 
junction box.

•  Connect the red and black leads from 

the appliance to the matching color 
wires in the junction box using UL/CSA 
listed wire connectors.

•  Connect the white wire from the 

appliance to the neutral white wire in the 
junction box using a UL/CSA listed wire 
connector.

A

cable from power supply

bw

black wires

B

junction box

gw

white-green or yellow-green wires

C

cable from range

rw

red wires

D

UL/CSA listed conduit connector

ww

white wires

Summary of Contents for TRU90X

Page 1: ...r flammable vapors or liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in yo...

Page 2: ...s burns to children or adults READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important We have provided many important safety messages throughout this manual and on the...

Page 3: ...ange for the first time Keep these operating instructions in a safe place and pass them on to any future user NOTE This range is manufactured for use with natural gas To convert the appliance to LP Pr...

Page 4: ...70 ELECTRICAL CODE latest edition Or the CANADIAN ELECTRICAL CODE C22 11 1 and C22 2 No 01982 or latest edition and all local codes and ordinances IMPORTANT Observe all codes and ordinances in force...

Page 5: ...ppliance All adjustments and servicing must be performed by qualified installers or service technicians Do not leave the packing material around the home Sort the various items of waste and take them...

Page 6: ...15 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 35 889 mm min clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet 5 max upper...

Page 7: ...used in conjunction with the gas range unless the hood and range have been designed tested in accordance with ANSI Z21 1 and listed by an independent testing laboratory for combination use This type...

Page 8: ...nections should be made before the range is placed in its final position Ensure that the burner caps are correctly positioned on the burner bases on the rangetop Legs should be installed near to where...

Page 9: ...he slits on the sides Warning Electrical shock hazard Use extreme caution when drilling holes into the wall or floor There may be concealed electrical wiring located behind the wall or under the floor...

Page 10: ...s to the wall 4 Attach the two anti tip brackets to the wall using an appropriate fastener for example screws appropriate for the type of wall 5 Respect the heights indicated in the figures using the...

Page 11: ...ightening them too much since there will be other adjustments to make 2 After having positioned and leveled the appliance move the bracket close to the rear of the appliance and anchor it to the floor...

Page 12: ...utral conductor in usual manner Do not use an adaptor Do not use an extension cord Check with a qualified electrician if you are not sure whether the range is grounded Turn power supply off before con...

Page 13: ...Copies of the standards listed above may be obtained from National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02169 7471 CSA International 8501 East Pleasant Valley Road Cl...

Page 14: ...or yellow green wires from the white wires that extend out of the end of the appliance cable The ground wire must be connected first Connect the green or yellow green ground wire from the appliance to...

Page 15: ...air supply in accordance with the standards in force The room where the appliance is installed must have enough air flow for the regular combustion of gas and the necessary air change in the room itse...

Page 16: ...nections indicate a leak If a leak appears shut off the gas valve controls and adjust the connections Then check the connections again Remove all the detergent product from the range Replace the parts...

Page 17: ...ting of that system at test pressures greater than 1 2 psig 3 5 kPa Testing below 112 PSI 3 5 kPa with a water column pressure of 14 35 6 cm gauge or lower The range must be isolated from the gas supp...

Page 18: ...ws under the top B to secure the backguard Mounting the kick platet The kick plate must always be positioned and secured correctly on the appliance 1 Place the kick plate in the front bottom part of t...