background image

Installation

14

1.5 Electrical requirements

Make sure that the power line rating 
matches the specifications indicated on the 
ID plate. The ID Plates are visibly located 
on the back of the appliance and on the 
oven door frame.

These ID plates must never be removed.

Warning

Electrical shock hazard

•  Frame grounded by connection of 

grounding lead to neutral lead. If used in 
a mobile home or if local codes do not 
permit grounding through neutral, open 
connection and use grounding lead to 
ground unit in accordance with local 
codes. Connect neutral lead to branch-
circuit neutral conductor in usual manner.

•  Do not use an adaptor.
•  Do not use an extension cord.
•  Check with a qualified electrician if you 

are not sure whether the range is 
grounded.

•  Turn power supply off before connecting 

wires.

•  Electrically ground the range.
•  Failure to follow these instructions can 

result in loss of life, fire, or electrical 
shock.

•  Improperly connecting the appliance 

grounding conductor can result in a risk 
of electrical shock. Check with a 
qualified electrician or serviceman if you 
are in doubt as to whether the appliance 
is properly grounded. Do not modify the 
power supply cord. If it does not fit in the 
outlet, have a proper outlet installed by 
a qualified electrician.

FAILURE TO FOLLOW THESE 
INSTRUCTIONS COULD 
RESULT IN LOSS OF LIFE, FIRE 
OR ELECTRICAL SHOCK.

Summary of Contents for TRU90X

Page 1: ...r flammable vapors or liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in yo...

Page 2: ...s burns to children or adults READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important We have provided many important safety messages throughout this manual and on the...

Page 3: ...ange for the first time Keep these operating instructions in a safe place and pass them on to any future user NOTE This range is manufactured for use with natural gas To convert the appliance to LP Pr...

Page 4: ...70 ELECTRICAL CODE latest edition Or the CANADIAN ELECTRICAL CODE C22 11 1 and C22 2 No 01982 or latest edition and all local codes and ordinances IMPORTANT Observe all codes and ordinances in force...

Page 5: ...ppliance All adjustments and servicing must be performed by qualified installers or service technicians Do not leave the packing material around the home Sort the various items of waste and take them...

Page 6: ...15 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 35 889 mm min clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet 5 max upper...

Page 7: ...used in conjunction with the gas range unless the hood and range have been designed tested in accordance with ANSI Z21 1 and listed by an independent testing laboratory for combination use This type...

Page 8: ...nections should be made before the range is placed in its final position Ensure that the burner caps are correctly positioned on the burner bases on the rangetop Legs should be installed near to where...

Page 9: ...he slits on the sides Warning Electrical shock hazard Use extreme caution when drilling holes into the wall or floor There may be concealed electrical wiring located behind the wall or under the floor...

Page 10: ...s to the wall 4 Attach the two anti tip brackets to the wall using an appropriate fastener for example screws appropriate for the type of wall 5 Respect the heights indicated in the figures using the...

Page 11: ...ightening them too much since there will be other adjustments to make 2 After having positioned and leveled the appliance move the bracket close to the rear of the appliance and anchor it to the floor...

Page 12: ...utral conductor in usual manner Do not use an adaptor Do not use an extension cord Check with a qualified electrician if you are not sure whether the range is grounded Turn power supply off before con...

Page 13: ...Copies of the standards listed above may be obtained from National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02169 7471 CSA International 8501 East Pleasant Valley Road Cl...

Page 14: ...or yellow green wires from the white wires that extend out of the end of the appliance cable The ground wire must be connected first Connect the green or yellow green ground wire from the appliance to...

Page 15: ...air supply in accordance with the standards in force The room where the appliance is installed must have enough air flow for the regular combustion of gas and the necessary air change in the room itse...

Page 16: ...nections indicate a leak If a leak appears shut off the gas valve controls and adjust the connections Then check the connections again Remove all the detergent product from the range Replace the parts...

Page 17: ...ting of that system at test pressures greater than 1 2 psig 3 5 kPa Testing below 112 PSI 3 5 kPa with a water column pressure of 14 35 6 cm gauge or lower The range must be isolated from the gas supp...

Page 18: ...ws under the top B to secure the backguard Mounting the kick platet The kick plate must always be positioned and secured correctly on the appliance 1 Place the kick plate in the front bottom part of t...