Installation
69
EN
Burner and nozzle characteristics tables
1 Natural Gas G20
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
1.0
1.8
2.9
1.1
3.9
Nozzle diameter (1/100 mm)
72
97
115
80
145
Pre-chamber (printed on nozzle)
(X)
(Z)
(Y)
(H1)
(H4)
Reduced capacity (W)
400
500
800
400
1600
2 Natural Gas G20
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
1.1
1.8
2.9
1.1
3.9
Nozzle diameter (1/100 mm)
72
94
108
75
135
Pre-chamber (printed on nozzle)
(X)
(Z)
(H8)
(H1)
(H4)
Reduced capacity (W)
400
500
800
400
1600
3 Natural Gas G25
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
1.0
1.8
2.9
1.0
4.0
Nozzle diameter (1/100 mm)
72
94
121
80
150
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F2)
(H1)
(H4)
Reduced capacity (W)
400
500
800
400
1600
4 Natural Gas G25.1
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
1.1
1.8
3.0
1.0
4.0
Nozzle diameter (1/100 mm)
77
100
134
80
155
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(H1)
(H4)
Reduced capacity (W)
400
500
800
400
1600
5 Natural Gas G25
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
1.0
1.8
2.9
1.1
3.9
Nozzle diameter (1/100 mm)
77
100
134
85
155
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(H1)
(H4)
Reduced capacity (W)
400
500
800
400
1600
6 Natural Gas G27
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
1.0
1.8
2.9
1.0
3.9
Nozzle diameter (1/100 mm)
77
105
138
85
160
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(H1)
(H4)
Reduced capacity (W)
400
500
800
400
1600
7 Natural Gas G2.350
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
1.0
1.8
2.9
1.0
4.0
Nozzle diameter (1/100 mm)
94
120
165
100
200
Pre-chamber (printed on nozzle)
(Y)
(Y)
(F3)
(0)
(H4)
Reduced capacity (W)
400
500
800
400
1600