Cleaning and maintenance
61
EN
Regeneration of self-cleaning panels
(catalytic cycle)
The regeneration cycle of the self-cleaning
panels is a cleaning method through
heating suitable for removing small grease
residues, not sugar-based ones.
1. Clean the base and the upper guard first
with a microfibre cloth soaked in water
and neutral washing up liquid. Rinse
thoroughly.
2. Set a regeneration cycle by selecting a
fan assisted function at the maximum
temperature for one hour.
3. If the panels are particularly dirty after the
regeneration cycle, remove them and
wash them with neutral washing up
liquid. Rinse and dry them.
Put the panels back in the oven and set a
fan-assisted function at a temperature of
180°C for one hour, in order to ensure that
they are thoroughly dry.
4.6 Extraordinary maintenance
Replacing the internal light bulb
1. Completely remove all accessories from
inside the oven.
2. Remove the racks/trays support frames.
3. Remove the bulb cover using a tool (e.g.
a screwdriver).
We recommend carrying out the
self-cleaning panel regeneration
cycle every 15 days.
Live parts
Danger of electrocution
• Disconnect the oven power supply.