Rev.
00
GW2045 – GW1060 Manual
Pag. 35 di 43
fig. 14 - Rear of 1060, position of pumps from top to bottom respectively. P1, P2, P3
7.5.2. DETERGENT CAN LEVEL SENSORS
The machine can also be fitted with built-in level sensors in the detergent suction pipes, smeg product "KIT
WD-LS3060".
IMPORTANT
The level sensors must be electrically connected, using:
1.
GW2045
: The terminal board on the plate fixed to the rear bar.
2.
GW1060
: The terminal board on the inner rear side (there is a terminal board for
connection of the relative level sensor for each peristaltic pump).
This operation must be carried out by specialised authorised staff.
fig. 15 - Optional suction pipe with built-in level sensor.