4. GENERAL SPECIFICATIONS
4.1. TECHNICAL FEATURES
ELECTRICAL
POWER
SUPPLY
GW2045
T
YPE OF
V
OLTAGE
[tolerated variation
±
±
±
±
10%]
230V ~
F
REQUENCY
[H
Z
]
50
P
OWER
R
ATING
[
K
W]
3.3
ELECTRICAL
POWER
SUPPLY
GW1060
M
ODELS
GW1060
GW1060
GW1060-3
GW1060-1
V
ERSION
Triphase 400V
Triphase 230V
Monophase 230V
T
YPE OF
V
OLTAGE
[variaz. variation
±
±
±
±
10%]
∼
400V 3/N/E
∼
230V 3/PE
∼
230V 1/N/PE
F
REQUENCY
[H
Z
]
50
P
OWER
R
ATING
[
K
W]
7 kW
7 kW
2.8 kW
A
UTOMATIC SWITCH ON MACHINE
(I
CN IS THE NOMINAL SWITCH POWER DURING
SHORT CIRCUIT
)
In 16A 3P+N 400V Icn
4500 A
In 20A 3P 400V Icn
6000 A
In 16 A P+N 230V Icn
4500 A
DATA
CONNECTION
–
FOR
ALL
MODELS
COMMUNICATION
WITH
PRINTER
DOOR RS232
W
ATER
S
UPPLY
-
FOR ALL MODELS
T
YPE OF WATER
C
OLD
W
ATER
D
EMINERALISED
W
ATER
P
RESSURE
[B
AR
]
2 – 5
2 - 5
M
IN
-
MAX
C
APACITY
[
L
/
MIN
]
4-10
4-10
T
YPE OF
C
ONNECTION
3/4”
3/4”
MAX
H
ARDNESS
[°f]
/
C
ONDUCTIVITY
[
µ
µ
µ
µ
S/
CM
]
42°f
Max 20
µ
S
I
RON
[
PPM
]
F
E MAX
< 0.5
WATER
DRAINAGE
FROM FLOOR LEVEL (on which machine is placed)
H
EIGHT
[
MM
]
Min 400 - Max 800
D
IAMETER
[
MM
]
Min 40