Instructions for the installer
102
12.3 Final operations
After replacing the nozzles, reposition the flame-spreader crowns, the burner
caps and the pan stands.
Following adjustment to a gas other than the one originally set in the factory,
replace the gas setting label fixed to the appliance with the one corresponding
to the new gas. The label is inserted inside the nozzle pack (where present).
12.3.1 Adjusting the minimum setting for natural and city gas
Light the burner and turn it to the minimum position. Extract
the gas tap knob and turn the adjustment screw next to the
tap rod (depending on the model) until the correct minimum
flame is achieved.
Refit the knob and verify that the burner flame is stable (when
turning the knob rapidly from the maximum to the minimum
position the flame must not go out). Repeat the operation on
all the gas taps.
12.3.2 Adjusting the minimum setting for LPG
In order to adjust the minimum setting with LPG, the screw at the side of the tap
rod must be tightened clockwise all the way.