Instructions for the installer
98
POSSIBLE
CONNECTION TYPES
CABLE TYPE
(if not present)
220
-
240 V
1N~
3-pole
3 x 1.5
mm²
H05V2V2-F
• Use H05V2V2-F cables withstanding temperatures of 90°C or higher.
• The values indicated above refer to the cross-section of the internal
conductor.
• The tightening torque of the screws of the terminal supply wires must be 1.5
- 2 Nm.
The aforementioned power cables are sized taking into account the coincidence
factor (in compliance with standard EN 60335-2-6).
11.5 Positioning the skirt
WARNING: The skirt provided is an integral part of the product; it must be
fastened to the appliance prior to installation.
• Position the skirt above the top, taking care
to align holes
A
with holes
B
.
• Secure the skirt to the top by tightening
screws
C
.
11.6 Positioning and levelling the appliance
After making the electrical and/or gas connections, properly level
the appliance on the floor to ensure better stability. Screw or
unscrew the bottom part of the foot until the appliance is stable and
level on the floor.