Instructions for the installer
34
7.3 Connecting the gas cylinder to the appliance
All the adjustments necessary to allow the appliance to function correctly are made in the factory. The
only procedure required for correct operation is connection of the hose supplied with the appliance, as
described below.
This product is designed to use
only LPG gas
sold in suitable cylinders obtainable from specialist
outlets. The appliance comes complete with a rubber hose with pressure regulator and connectors. The
pressure regulator is adjusted in the factory to provide optimum operation of the product.
The product is factory-set to work with LPG. Should it be necessary to change the type of gas, and
therefore the diameter of the nozzles, contact the nearest Authorised Service Centre.
Nozzles and instructions for setting the product to operate with
NATURAL
gas are provided. Contact the
nearest Authorised Service Centre.
If operation is not optimal, DO NOT ATTEMPT TO REPAIR THE APPLIANCE, but contact the nearest
Authorised Service Centre.
For assembling or replacing the hose (periodically check its expiration date), you must refer to the
applicable regulations.
7.4 Burner, nozzle and gas consumption characteristics tables
Burner
Rated
heating
capacity (kW)
LPG – G30/G31 30/37 mbar
Nozzle
diameter
1/100 mm
By-pass
1/100 mm
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Left
4.5
100
85
2200
327
321
Centre (BQ91T-1)
4.5
100
85
2200
327
321
Right
4.5
100
85
2200
327
321
Radiant grill (BQ61T-1)
3.8
95
Reg.
2500
276
271
Radiant grill (BQ91T-1)
4.5
105
Reg.
2700
327
321
7.5 Check for any gas leaks
These operations must be carried out when the barbecue is connected for the first time and
every time that it is disconnected and reconnected to the gas supply.
Once the barbecue hose has been connected to the gas supply (LPG), proceed as follows:
1 Open the gas valve on the LPG cylinder (or rotate the tap for the Natural Gas supply),
BUT DO NOT
ATTEMPT TO LIGHT THE BURNERS
.
2 With gas pressure in the hose, check for any leaks on all the connections using a soap and water
solution.
Never use a naked flame to check for leaks.
3 In the event that there is a leak, bubbles will appear on the faulty connection where the gas is
escaping.
4 Close the gas tap of the gas cylinder
,
tighten the leaking connection and then repeat the test.
5 If the gas leak persists, contact the nearest supplier.
NEVER USE A FLAME TO DETECT LEAKS.