background image

 

QuickServer Start-Up Guide 

Page 44 of 71 

Dur_Act_Day_7   

AI 77 

30153-30154 

Dur_Act_Day_8   

AI 78 

30155-30156 

Dur_Act_Day_9   

AI 79 

30157-30158 

Dur_Act_Day_10  

AI 80 

30159-30160 

Energy_T_WH_1   

AI 81 

30161-30162 

Energy_T_WH_2   

AI 82 

30163-30164 

Energy_T_WH_3   

AI 83 

30165-30166 

Energy_T_WH_4   

AI 84 

30167-30168 

Energy_T_WH_5   

AI 85 

30169-30170 

Energy_T_WH_6   

AI 86 

30171-30172 

Energy_T_WH_7   

AI 87 

30173-30174 

Energy_T_WH_8   

AI 88 

30175-30176 

Energy_T_WH_9   

AI 89 

30177-30178 

Energy_T_WH_10  

AI 90 

30179-30180 

Energy_T_J_1    

AI 91 

30181-30182 

Energy_T_J_2    

AI 92 

30183-30184 

Energy_T_J_3    

AI 93 

30185-30186 

Energy_T_J_4    

AI 94 

30187-30188 

Energy_T_J_5    

AI 95 

30189-30190 

Energy_T_J_6    

AI 96 

30191-30192 

Energy_T_J_7    

AI 97 

30193-30194 

Energy_T_J_8    

AI 98 

30195-30196 

Energy_T_J_9    

AI 99 

30197-30198 

Energy_T_J_10   

AI 100 

30199-30200 

Voltage_1       

AI 101 

30201-30202 

Voltage_2       

AI 102 

30203-30204 

Voltage_3       

AI 103 

30205-30206 

Voltage_4       

AI 104 

30207-30208 

Voltage_5       

AI 105 

30209-30210 

Voltage_6       

AI 106 

30211-30212 

Voltage_7       

AI 107 

30213-30214 

Voltage_8       

AI 108 

30215-30216 

Voltage_9       

AI 109 

30217-30218 

Voltage_10      

AI 110 

30219-30220 

Current_1       

AI 111 

30221-30222 

Current_2       

AI 112 

30223-30224 

Current_3       

AI 113 

30225-30226 

Current_4       

AI 114 

30227-30228 

Current_5       

AI 115 

30229-30230 

Current_6       

AI 116 

30231-30232 

Current_7       

AI 117 

30233-30234 

Current_8       

AI 118 

30235-30236 

Current_9       

AI 119 

30237-30238 

Current_10      

AI 120 

30239-30240 

Temp_Ext_1      

AI 121 

30241-30242 

Temp_Ext_2      

AI 122 

30243-30244 

Temp_Ext_3      

AI 123 

30245-30246 

Temp_Ext_4      

AI 124 

30247-30248 

Temp_Ext_5      

AI 125 

30249-30250 

Temp_Ext_6      

AI 126 

30251-30252 

Temp_Ext_7      

AI 127 

30253-30254 

Temp_Ext_8      

AI 128 

30255-30256 

Temp_Ext_9      

AI 129 

30257-30258 

Temp_Ext_10     

AI 130 

30259-30260 

Temp_Flow_1     

AI 131 

30261-30262 

Temp_Flow_2     

AI 132 

30263-30264 

Temp_Flow_3     

AI 133 

30265-30266 

Temp_Flow_4     

AI 134 

30267-30268 

Temp_Flow_5     

AI 135 

30269-30270 

Temp_Flow_6     

AI 136 

30271-30272 

Temp_Flow_7     

AI 137 

30273-30274 

Temp_Flow_8     

AI 138 

30275-30276 

Temp_Flow_9     

AI 139 

30277-30278 

Temp_Flow_10    

AI 140 

30279-30280 

Temp_Ret_1      

AI 141 

30281-30282 

Temp_Ret_2      

AI 142 

30283-30284 

Temp_Ret_3      

AI 143 

30285-30286 

Temp_Ret_4      

AI 144 

30287-30288 

Temp_Ret_5      

AI 145 

30289-30290 

Temp_Ret_6      

AI 146 

30291-30292 

Temp_Ret_7      

AI 147 

30293-30294 

Temp_Ret_8      

AI 148 

30295-30296 

Temp_Ret_9      

AI 149 

30297-30298 

Temp_Ret_10     

AI 150 

30299-30300 

Temp_Dif_1      

AI 151 

30301-30302 

Temp_Dif_2      

AI 152 

30303-30304 

Temp_Dif_3      

AI 153 

30305-30306 

Temp_Dif_4      

AI 154 

30307-30308 

Temp_Dif_5      

AI 155 

30309-30310 

Temp_Dif_6      

AI 156 

30311-30312 

Temp_Dif_7      

AI 157 

30313-30314 

Temp_Dif_8      

AI 158 

30315-30316 

Temp_Dif_9      

AI 159 

30317-30318 

Temp_Dif_10     

AI 160 

30319-30320 

Time_Sec_1      

AI 161 

30321-30322 

Time_Sec_2      

AI 162 

30323-30324 

Time_Sec_3      

AI 163 

30325-30326 

Time_Sec_4      

AI 164 

30327-30328 

Time_Sec_5      

AI 165 

30329-30330 

Time_Sec_6      

AI 166 

30331-30332 

Time_Sec_7      

AI 167 

30333-30334 

Time_Sec_8      

AI 168 

30335-30336 

Time_Sec_9      

AI 169 

30337-30338 

Time_Sec_10     

AI 170 

30339-30340 

Time_Min_1      

AI 171 

30341-30342 

Time_Min_2      

AI 172 

30343-30344 

Time_Min_3      

AI 173 

30345-30346 

Time_Min_4      

AI 174 

30347-30348 

Time_Min_5      

AI 175 

30349-30350 

Time_Min_6      

AI 176 

30351-30352 

Time_Min_7      

AI 177 

30353-30354 

Time_Min_8      

AI 178 

30355-30356 

Time_Min_9      

AI 179 

30357-30358 

Time_Min_10     

AI 180 

30359-30360 

Time_Hrs_1      

AI 181 

30361-30362 

Time_Hrs_2      

AI 182 

30363-30364 

Time_Hrs_3      

AI 183 

30365-30366 

Time_Hrs_4      

AI 184 

30367-30368 

Time_Hrs_5      

AI 185 

30369-30370 

Time_Hrs_6      

AI 186 

30371-30372 

Time_Hrs_7      

AI 187 

30373-30374 

Time_Hrs_8      

AI 188 

30375-30376 

Time_Hrs_9      

AI 189 

30377-30378 

Time_Hrs_10     

AI 190 

30379-30380 

Time_Days_1     

AI 191 

30381-30382 

Time_Days_2     

AI 192 

30383-30384 

Time_Days_3     

AI 193 

30385-30386 

Time_Days_4     

AI 194 

30387-30388 

Time_Days_5     

AI 195 

30389-30390 

Time_Days_6     

AI 196 

30391-30392 

Time_Days_7     

AI 197 

30393-30394 

Time_Days_8     

AI 198 

30395-30396 

Time_Days_9     

AI 199 

30397-30398 

Time_Days_10    

AI 200 

30399-30400 

Time_Op_Sec_1   

AI 201 

30401-30402 

Time_Op_Sec_2   

AI 202 

30403-30404 

Time_Op_Sec_3   

AI 203 

30405-30406 

Time_Op_Sec_4   

AI 204 

30407-30408 

Time_Op_Sec_5   

AI 205 

30409-30410 

Time_Op_Sec_6   

AI 206 

30411-30412 

Time_Op_Sec_7   

AI 207 

30413-30414 

Time_Op_Sec_8   

AI 208 

30415-30416 

Time_Op_Sec_9   

AI 209 

30417-30418 

Time_Op_Sec_10  

AI 210 

30419-30420 

Time_Op_Min_1   

AI 211 

30421-30422 

Time_Op_Min_2   

AI 212 

30423-30424 

Time_Op_Min_3   

AI 213 

30425-30426 

Time_Op_Min_4   

AI 214 

30427-30428 

Summary of Contents for FieldServer FS-QS-1 0 Series

Page 1: ...Document Revision 2 J T18600 FieldServer QuickServer Start up Guide FS QS 1011 12X0 12X1 1X50 1X51 APPLICABILITY EFFECTIVITY Effective for all systems manufactured after July 2020...

Page 2: ...ical support needs related to the FieldServer product MSA Safety 1991 Tarob Court Milpitas CA 95035 Website www sierramonitor com U S Support Information 1 408 964 4443 1 800 727 4377 Email smc suppor...

Page 3: ...e 21 6 2 Connect the PC to the QuickServer Over the Ethernet Port 21 6 3 Connecting to the QuickServer 22 6 3 1 Using the FieldServer Toolbox to Discover and Connect to the QuickServer 22 6 3 2 Using...

Page 4: ...UF 280T Mappings to BACnet and Modbus 46 Appendix B 15 SensusHRI B1 8Profile Mappings to BACnet and Modbus 47 Appendix B 16 KromSchroderTRZ2S1 Mappings to BACnet and Modbus 47 Appendix B 17 KromSchrod...

Page 5: ...2 Change FieldServer Password 66 Appendix D Reference 67 Appendix D 1 LED Functions 67 Appendix D 2 QuickServer FS QS 101X DCC 68 Appendix D 3 QuickServer 1XXX Part Numbers 68 Appendix D 4 Compliance...

Page 6: ...19 Warning Expanded Text 24 Figure 20 FieldServer Login 24 Figure 21 Security Mode Selection Screen 25 Figure 22 Security Mode Selection Screen 26 Figure 23 FS GUI Landing Page 27 Figure 24 FS GUI Ne...

Page 7: ...lected drivers on the FS QS 1X11 and FS QS 12X1 one of those drivers is LonWorks A sample configuration file is also pre loaded onto the QuickServer All instruction manuals driver manuals support util...

Page 8: ...mation about the BACnet Testing Laboratory Click here for the BACnet PIC Statement LonMark International is the recognized authority for certification education and promotion of interoperability stand...

Page 9: ...S 8915 35 QS WARNING Install only as instructed failure to follow the installation guidelines or using screws without the DIN rail mounting bracket could result in permanent damage to the product If t...

Page 10: ...QuickServer Start Up Guide Page 10 of 71 4 2 Dimensions 4 2 1 Dimension Drawing FS QS 1X10 XXXX R1 Port R2 Port Figure 2 FS QS 1X10 XXXX...

Page 11: ...QuickServer Start Up Guide Page 11 of 71 4 2 2 Dimension Drawing FS QS 1XX1 XXXX LonWorks Port R2 Port Figure 3 FS QS 1XX1 XXXX...

Page 12: ...QuickServer Start Up Guide Page 12 of 71 4 2 3 Dimension Drawing FS QS 123X Models with RS 422 R1 Port R2 Port Figure 4 FS QS 123X models with RS 422...

Page 13: ...t false bits of data from being detected The bias resistors typically pull one line high and the other low far away from the decision point of the logic In the RS 485 carrier the bias resistor is 510...

Page 14: ...ation Resistor Termination resistors are also used to reduce noise These pull the two lines of an idle bus together However they would override the effect of any bias resistors if connected Terminatio...

Page 15: ...ther power supply requirements Position A The Carrier makes use of a full wave rectifying bridge Can be used for 12 24VAC input or 9 30VDC input At 9VDC this becomes marginal Position B The Carrier ma...

Page 16: ...er NOTE The following only applies to models FS QS 1A50 FS QS 1A51 FS QS 1B51 FS QS 1B51 FS QS 1C51 and FS QS 1C51 The Master Slave jumper is used to set the M Bus hardware as a Master or Slave device...

Page 17: ...ced below o The default factory setting is OFF switch position right side o To enable biasing turn the bias switch ON switch position left side NOTE Biasing only needs to be enabled on one device The...

Page 18: ...200 38400 57600 115200 For connection details to RS 232 or RS 422 refer to Appendix A 1 5 1 2 RS 485 Connection R1 Port NOTE The following only applies to non LonWorks QuickServers with an RS 435 R1 p...

Page 19: ...sure to access the Service Pin See the instructions on the QuickServer as to which way to toggle the screwdriver during commissioning 5 3 QuickServer KNX FS QS 124X XXXX Connect the QuickServer to the...

Page 20: ...Connection R2 Port only available on FS QS 122X Models Refer to Appendix A2 for further hardware connection options The following Baud Rates are supported on the R2 Port 4800 9600 19200 38400 57600 1...

Page 21: ...D terminal The QuickServer is factory set for 9 30V DC or 12 24V AC 6 2 Connect the PC to the QuickServer Over the Ethernet Port Connect an Ethernet cable between the PC and QuickServer or connect the...

Page 22: ...ckServer and launch the FS GUI NOTE If the connect button is greyed out the QuickServer s IP Address must be set to be on the same network as the PC Section 8 1 6 3 2 Using a Web Browser to Connect to...

Page 23: ...rusted This will cause the following pop up windows to appear When the Web Server Security Unconfigured window appears read the text and choose whether to move forward with HTTPS or HTTP When the warn...

Page 24: ...default is admin and the Password found on the label of the FieldServer NOTE There is also a QR code in the top right corner of the FieldServer label that shows the default unique password when scann...

Page 25: ...l appear that allows the user to select which mode the FieldServer should use NOTE Cookies are used for authentication NOTE To change the web server security mode after initial setup go to Appendix C...

Page 26: ...ivate Key text into their respective fields If the Private Key is encrypted type in the associated Passphrase Click Save A Redirecting message will appear After a short time the Web Configurator page...

Page 27: ...tton see Figure 23 allows users to connect to the SMC Cloud MSA Safety s device cloud solution for IIoT The SMC Cloud enables secure remote connection to field devices through a FieldServer and its lo...

Page 28: ...w Subnet Mask If necessary change the IP Gateway Default Gateway field Type in a new IP Gateway NOTE If the FieldServer is connected to a router the IP Gateway of the FieldServer should be set to the...

Page 29: ...gisters in the Config csv file for the initial start up If not the product is shipped with a sample config csv that shows an example of the drivers ordered In the main menu of the FS GUI screen go to...

Page 30: ...hen File Transfer and finally Update Browse and select the csv file open then click Submit Once download is complete a message bar will appear confirming that the configuration was updated successfull...

Page 31: ...menu of the FS GUI screen click Setup then File Transfer Click the config csv link under the Retrieve heading in the middle section of the screen o The file will automatically download to the web bro...

Page 32: ...the number of messages on each protocol 8 5 1 Accessing SMC Cloud The SMC Cloud button see Figure 23 allows users to connect to the SMC Cloud MSA Safety s device cloud solution for IIoT The SMC Cloud...

Page 33: ...r to peer high speed communication when low bus latency is required very few devices on the bus Its usage is very specific to client installations requirements NOTE The RS 232 looks similar to the RS...

Page 34: ...ignals may be crossed Pin 5 SHD Shield connection must be connected on at least one side of the bus but not necessarily on both sides POWER Connector Please note that AC voltage is not supported on th...

Page 35: ...arms etc This allows BMS systems to access a KNX network using direct read and write or with KNX configured groups This setup does not require the use of ETS4 to configure the QuickServer KNX gateway...

Page 36: ...kServer Gateway is configurable to act as both a Master and a Slave M Bus device The M Bus Connector consist of a and terminal Most M Bus Devices are not polarity sensitive although the polarity of th...

Page 37: ...secure Modbus TCP connection on port 1502 Appendix A 4 1 1 Simple Secure Server Configuration Add TLS_Port parameter in the connections section of the configuration file and set to a port number betwe...

Page 38: ...er with the following connection settings Connections Adapter Protocol TLS_Port Validate_Client_Cert Cert_Authority_File N1 Modbus TCP 1502 Yes my_authorized_clients pem This configuration has the Fie...

Page 39: ...ymously known as common name host name or domain etc The common name can be obtained by the following methods Ask the certificate issuer for the host name Use online tools to decode the certificate fo...

Page 40: ...rtificate against its own internal authority file before finalizing the connection By default this means the FieldServer will only establish connections to other FieldServers Remote_Node_TLS_Port Vali...

Page 41: ...5 30016 RH_Avg AI 09 30017 30018 Appendix B 4 EMU 3PH Power 3 85 Mappings to BACnet and Modbus Point Name BACnet Modbus MBUS_Meter_ node_id_Alarms AI 01 30001 30002 Energy_WH_1 AI 02 30003 30004 Energ...

Page 42: ...Vol_Flo_L_H_1 AI 36 30071 30072 Vol_Flo_L_H_2 AI 37 30073 30074 Vol_Flo_L_H_3 AI 38 30075 30076 Vol_Flo_L_H_4 AI 39 30077 30078 Vol_Flo_L_H_5 AI 40 30079 30080 Vol_Flo_L_H_6 AI 41 30081 30082 Vol_Flo...

Page 43: ...Avg_M_4 AI 14 30027 30028 Dur_Avg_M_5 AI 15 30029 30030 Dur_Avg_M_6 AI 16 30031 30032 Dur_Avg_M_7 AI 17 30033 30034 Dur_Avg_M_8 AI 18 30035 30036 Dur_Avg_M_9 AI 19 30037 30038 Dur_Avg_M_10 AI 20 30039...

Page 44: ...AI 142 30283 30284 Temp_Ret_3 AI 143 30285 30286 Temp_Ret_4 AI 144 30287 30288 Temp_Ret_5 AI 145 30289 30290 Temp_Ret_6 AI 146 30291 30292 Temp_Ret_7 AI 147 30293 30294 Temp_Ret_8 AI 148 30295 30296 T...

Page 45: ...Pressure_9 AI 279 30557 30558 Pressure_10 AI 280 30559 30560 Mass_1 AI 281 30561 30562 Mass_2 AI 282 30563 30564 Mass_3 AI 283 30565 30566 Mass_4 AI 284 30567 30568 Mass_5 AI 285 30569 30570 Mass_6 A...

Page 46: ...0818 Alarm_Flags_10 AI 410 30819 30820 Appendix B 12 Kamstrup 66 Mappings to BACnet and Modbus Point Name BACnet Modbus Energy_T_WH_1 AI 01 30001 30002 Energy_T_WH_2 AI 02 30003 30004 Energy_T_WH_3 AI...

Page 47: ..._Avg_D_4 AI 034 30067 30068 Dur_Avg_D_5 AI 035 30069 30070 Dur_Avg_D_6 AI 036 30071 30072 Dur_Avg_D_7 AI 037 30073 30074 Dur_Avg_D_8 AI 038 30075 30076 Dur_Avg_D_9 AI 039 30077 30078 Dur_Avg_D_10 AI 0...

Page 48: ...6 Time_Sec_4 AI 164 30327 30328 Time_Sec_5 AI 165 30329 30330 Time_Sec_6 AI 166 30331 30332 Time_Sec_7 AI 167 30333 30334 Time_Sec_8 AI 168 30335 30336 Time_Sec_9 AI 169 30337 30338 Time_Sec_10 AI 170...

Page 49: ...ol_Flo_L_M_1 AI 301 30601 30602 Vol_Flo_L_M_2 AI 302 30603 30604 Vol_Flo_L_M_3 AI 303 30605 30606 Vol_Flo_L_M_4 AI 304 30607 30608 Vol_Flo_L_M_5 AI 305 30609 30610 Vol_Flo_L_M_6 AI 306 30611 30612 Vol...

Page 50: ...re 1 AI 16 30031 30032 Flow Temperature 2 AI 17 30033 30034 Flow Temperature 3 AI 18 30035 30036 Return Temperature 1 AI 19 30037 30038 Return Temperature 2 AI 20 30039 30040 Return Temperature 3 AI 2...

Page 51: ...0177 30178 Fabrication Number 1 AI 90 30179 30180 Fabrication Number 2 AI 91 30181 30182 Fabrication Number 3 AI 92 30183 30184 Appendix B 23 Kamstrup Multical Mappings to BACnet and Modbus Point Name...

Page 52: ...3 30134 Volume Flow 6 AI 68 30135 30136 Volume Flow 7 AI 69 30137 30138 Volume Flow 8 AI 70 30139 30140 Volume Flow 9 AI 71 30141 30142 Volume 1 AI 72 30143 30144 Volume 2 AI 73 30145 30146 Volume 3 A...

Page 53: ...stom_1 AI 5 30009 30010 Power_W_1 AI 6 30011 30012 Pressure_1 AI 7 30013 30014 Mass_1 AI 8 30015 30016 Vol_Flo_L_M_1 AI 9 30017 30018 Volume_1 AI 10 30019 30020 Unknown_1 AI 11 30021 30022 Unknown_2 A...

Page 54: ...Dif_3 AI 19 30037 30038 Time_Op_Hrs_1 AI 20 30039 30040 Time_Op_Hrs_2 AI 21 30041 30042 Time_Op_Hrs_3 AI 22 30043 30044 Power_W_1 AI 23 30045 30046 Power_W_2 AI 24 30047 30048 Power_W_3 AI 25 30049 30...

Page 55: ...in the PC s Device Manager List and that it is configured to run the TCP IP protocol Check that the IP netmask of the PC matches the QuickServer The Default IP Address of the QuickServer is 192 168 2...

Page 56: ...FieldServer Diagnostics page via one of the following methods o Open the FieldServer FS GUI page and click on Diagnostics in the Navigation panel o Open the FieldServer Toolbox software and click the...

Page 57: ...e diagnosis of the problem NOTE While all necessary documentation is shipped with the FieldServer on the USB flash drive these documents are constantly being updated Newer versions may be available on...

Page 58: ...ck on the Start Diagnostic button o Wait for the capture period to finish and the Diagnostic Test Complete window will appear Step 2 Send Log o Once the diagnostic test is complete a zip file is saved...

Page 59: ...ev 3 and higher NOTE Internet Explorer is no longer supported as recommended by Microsoft NOTE Computer and network firewalls must be opened for Port 80 to allow FieldServer GUI to function Appendix C...

Page 60: ...pendix C 4 1 Change Security Mode Click Security in the Navigation panel Click the Mode desired o If HTTPS with own trusted TLS certificate is selected follow instructions in Section 7 2 1 Click the S...

Page 61: ...will only be available if the security mode was previously setup as HTTPS with own trusted TLS certificate Click Security in the Navigation panel Click the Edit Certificate button to open the certific...

Page 62: ...the FieldServer Recovery Instructions document For QuickServer 2xx0 ProtoNode FPC N54 or ProtoAir recovery instructions see the FieldServer Next Gen Recovery document If the default unique password i...

Page 63: ...up and Password o User details are hashed and salted NOTE The password must meet the minimum complexity requirements An algorithm automatically checks the password entered and notes the level of stren...

Page 64: ...Click the pencil icon next to the desired user to open the User Edit window Once the User Edit window opens change the User Security Group and Password as needed Click Confirm Once the Success messag...

Page 65: ...Guide Page 65 of 71 Appendix C 5 1 3 Delete Users Click the trash can icon next to the desired user to delete the entry When the warning message appears click Confirm Figure 41 Setup Users Figure 42...

Page 66: ...ents An algorithm automatically checks the password entered and notes the level of strength on the top right of the Password text field NOTE If a gateway in the field is updated to a secure gateway th...

Page 67: ...starts flashing During the first 20 seconds the LED should be off ERR The ERR LED will go on solid 15 seconds after power up It will turn off after 5 seconds A steady red light will indicate there is...

Page 68: ...JCI Metasys N2 0117 SNMP BACnet IP 1047 SNMP LonWorks 1178 SNMP JCI Metasys N2 1154 SNMP BACnet MS TP 1200 BACnet MS TP LonWorks 0345 Appendix D 3 QuickServer 1XXX Part Numbers Field Connections Inte...

Page 69: ...y with local electrical code o Be suited to the expected operating temperature range o Meet the current and voltage rating for QuickServer Net Furthermore the interconnecting power cable shall o Be of...

Page 70: ...to167 F Surge Suppression EN61000 4 2 ESD EN61000 4 3 EMC EN61000 4 4 EFT Humidity 5 90 RH non condensing Figure 45 Specifications This device complies with part 15 of the FCC Rules Operation is subj...

Page 71: ...hich original identification marks have been removed or altered This Limited Warranty also will not apply to interconnecting cables or wires consumables or to any damage resulting from battery leakage...