-8-
No. TQ1230001-OM104-A
3. Specifications
3.1. Specifications
■
Product specifications
Common
Fluid
Air
Operating temperature range[°C]
5 to 50
Connector type
Molex connector(512270800)
8 Pin (Plug)
Weight [g]
ZXP7N11-X1*
671
ZXP7A11-X1*
895
Example)
ZXP7A11-ZPB25JS-X1
948 note1)
Max. workload [kg] Note2)
7
Impact / Vibration resistance [m/s
2
] Note3)
150 / 30
Air supply port(P)
One touch fitting (Φ4) Internal
Power supply voltage
[V]
DC24
±
10%
Vacuum
ejector
Max. vacuum pressure [kPa] note4)
-84
Max. suction flow [L/min(ANR)] note4)
17
Air consumption [L/min(ANR)] note4)
57
Supply pressure range [MPa]
0.3 to 0.55
Standard supply pressure [MPa] note5)
0.5
Valve
Model
V114
Pressure
switch
Model
ZSE20-*-*-M5-A1
Rated pressure range [kPa]
0 to -101
Display Accuracy [%]
±
2 F.S. ±1 digit
(Ambient temperature at 25°C
±3
°C)
Repeatability [%]
±
0.2 F.S. ±1 digit
Temperature characteristics [%]
±
2 F.S. (Standard on 25
°C)
Applicable suction cups
Refer to “3.4. How to order”
Note 1) The weight changes by the selected suction cup. Refer to “3.4 How to order”.
Note 2) Limited by the cup diameter, mounting orientation or workpiece. The weight of the workpiece shall be maximum
workload or less.
Gripping or transfer of workload exceeding the maximum workload leads to the decrease of vacuum due to air leakage.
Note 3) Impact resistance: The characteristics are satisfied after tested one time in each of the X, Y and Z directions without
energization. (Initial value)
Vibration resistance: The characteristics are satisfied after tested a one sweep in each of the X, Y and Z directions at 10
to 500 Hz without energization. (Initial value)
Note 4) Values at the standard supply pressure. Values are based on standard of SMC measurements. They depend on
atmospheric pressure (weather, altitude, etc.) and measurement method.
Note 5) This shows the pressure just before the supply (P) port.
The performance such as vacuum pressure may reduce, depending on supply air capacity, the piping volume (piping
length and diameter) and affection of air consumption of other devices which operate at the same time.