-20-
No. TQ1230001-OM104-A
(2) Mounting plugs and a
suction cup with adapter
Plug(M-3P)
(4 pcs)
Tighten by hand, and give it an
additional turn approx. 1/4
rotations with a wrench.
Suction cup with adapter
6. How to change the number of cups
6.1 Change to 1 cup (with flange)
1. Removal of the cup.
(1) Remove the suction
cup with adapter from plate B using a spanner.
(2) Loosen the bolt (M4 x 8), then remove plate B from plate A.
Be careful not to lose the O-ring.
(3) Loosen the bolt for sealing (M6X8), then remove the cup from plate A.
2. Mounting of the plug and suction cup with adapter
(1) Confirm the gasket seal in the accessory plug, then mount the plugs to plate A.
(4 places)
(2) Confirm the gasket seal in the adapter, then mount the suction cup with adapter removed in the
process (1) to plate A.
Reassemble the parts by reversing the disassembling process with specified tightening torque.
Caution
T
ightening torque: 1Nm, (As reference, tighten by 45 degrees using a spanner after tightening by hand))
If tightened excessively, thread portion may be damaged and gasket may be deformed. This will cause
air leakage. Insufficient tightening may loosen the thread or cause air leakage.
Completion drawing
(1) Disassemble the suction cups with adapter
Plate A
Hexagon socket button bolt (M6x8)
With gasket(M-6G)
Tightening torque 1±0.1N
・
m
Plate B (with O-ring)
Hexagon socket button bolt (M4x8)
Tightening torque 1.5±0.15N
・
m
Suction cup with adapter