(R)3
2(A)
1(P)
(R)3 1(P)
(R)3 1(P)
(R)3
2(A)
1(P)
2(A)
2(A)
Type of actuation
Series
VQZ 2 1 2
5 M
2
3
VQZ200 body width 15 mm
VQZ300 body width 18 mm
Body type
2
Body ported
Function
Manual override
Nil: Non-locking
push type
(Tool required)
B: Locking type
(Tool required)
C6
1
N.C.
2
N.O.
3
N.C.
4
N.O.
Coil voltage
1
2
3
4
5
6
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC [115 VAC] (50/60 Hz)
220 VAC [230 VAC] (50/60 Hz)
24 VDC
12 VDC
Note) For applicable One-touch fitting and silencer
models for this valve series, refer to back page
1828.
1
Port size [2(A) port]
—
—
—
—
—
VQZ200
ø4 One-touch fitting
ø6 One-touch fitting
ø8 One-touch fitting
ø10 One-touch fitting
M5 thread
Rc 1/4
C4
C6
C8
C10
M5
02
VQZ300
Port size
Symbol
Note) For inch size One-touch fittings and option thread
type, refer to page 1806.
+-
+-
Option
Nil:
F:
None
With bracket
+-
Bracket
Note 1) Semi-standard
Note 2) For details on external pilot type, refer to page 1806.
Note 3) For AC specification power consumption, refer to page 1794.
Use standard (DC) specification for
continuous duty.
Caution
Nil
Standard
High speed response type
High pressure type
(Metal seal type only)
External pilot type
B
Note 1)
K
Note 1)
R
Note 1, 2)
Symbol
Specifications
DC
(0.35 W)
(0.9 W)
Note 3)
(0.9 W)
—
—
AC
High pressure/External pilot type
(Metal seal type only)
KR
Note 1, 2)
—
High speed response/External
pilot type
BR
Note 1, 2)
(0.9 W)
(0.9 W)
—
IP65 compliant
Nil
W
Note)
—
Compliant
Note) VQZ200/300 DIN
terminal rubber
seal only (except
external pilot). For
details on IP65
enclosure, refer to
page 1806.
VQZ200/300
/ How to Order Valve
Note) AC-type models that are
CE-compliant have DIN
terminals only.
CE-compliant
—
CE-compliant
Nil
Q
Made to Order
(For details, refer to pages 1794 and 1825.)
Note) AC-type models that
are CE-compliant have
DIN terminals only.
[Option]
Metal seal
Rubber seal
Electrical entry
G: Grommet
(DC speci-
fication)
L: L-type plug
connector
with lead
wire
LO: L-type plug
connector
without
connector
M: M-type plug
connector
with lead
wire
MO: M-type plug
connector
without
connector
With light/
surge voltage
suppressor
With light/
surge voltage
suppressor
With light/
surge voltage
suppressor
With light/
surge voltage
suppressor
Y: DIN
terminal
YO: DIN
terminal
without
connector
YZ: DIN
terminal
YOS: DIN
terminal
without
connector
(DC speci-
fication)
With surge
voltage
suppressor
YS: DIN
terminal
(DC speci-
fication)
With surge
voltage
suppressor
With light/
surge voltage
suppressor
Note 1) Standard lead wire length: 300 mm
Note 2) For AC voltage valves there is no “S” type. It is already built-in to the rectifier
circuit.
+ –
-
+
+
–
CE-
compliant
CE-
compliant
AC
DC
AC
DC
Body Ported
Series
VQZ100/200/300
Note 2)
Note 2)
1793
SYJ
VQZ
VP
VG
VP3
VQZ