![SMC Networks VQZ100 Series Manual Download Page 35](http://html1.mh-extra.com/html/smc-networks/vqz100-series/vqz100-series_manual_1299466035.webp)
Thread type
(Cylinder port and 1(P),
3(R) ports of sub-plate)
Nil
N
T
F
Rc
NPT
NPTF
G
External pilot port
Note) The pilot exhaust IP65 valves is common with main valve exhaust.
(The standard valve has an individual exhaust for the pilot valve.)
Valve Part No.
External Pilot Specification
Manifold Part No.
Manifold Part No.
Inch Size One-touch Fittings and Optional Threads
The external pilot specification is used when the operating pressure is below the minimum operating pressure 0.1 to 0.15 MPa or when valve is used for a
vacuum application. Order a valve by adding the external pilot specification [R] to the part number.
Inch size One-touch fittings and NPT, NPTF and G thread are available.
Valve Part No.
Optional Threads Other than Rc
Rc specifications are standard for all ports, however, NPT, NPTF and G are available for overseas markets. Add the appropriate symbol following the port
size in the standard part number.
Entry is the same as standard products.
VQZ
5R
1
Entry is the same as standard products.
VV3QZ
5
C
VV3QZ
5
N7 T C
Entry is the same as
standard products.
VQZ
5
T
1
Entry is the same as standard products.
IP65 Enclosure (Based on IEC60529)
DIN terminal is available with IP65 enclosure.
Valve Part No.
(Applicable to the VQZ200/300 rubber seal with the exception of the external pilot type)
VQZ
Y
W1
5
2
3
Entry is the same as standard products.
Thread type
(Cylinder port and
1(P), 3(R) ports)
Nil
N
T
F
Rc
NPT
NPTF
G
Cylinder port
VQZ100
VQZ200
VQZ300
Cylinder port
Symbol
Applicable tubing O.D.
N1
N3
N7
N9 N11
ø1/8" ø5/32" ø1/4" ø5/16"
—
—
—
—
—
—
NM
Note 1)
Mixed
ø3/8"
Note 1) Except VQZ100, mixing One-touch fittings and thread types is impossible.
Note 2) Metric size One-touch fittings (C
) are also available.
M5
01
02
M5 thread 1/8 thread
—
—
—
—
—
—
1/4 thread
Pressure Specifications
–100 kPa to 0.7 MPa
Series
Operating pressure range
Note 1)
Metal seal
Rubber seal
(VQZ100: poppet)
VQZ100
Note 2)
VQZ200/300
—
0.2 to 0.7 MPa
0.1 to 0.7 MPa
0.15 to 0.7 MPa
Note 1) In case of the high pressure type, upper limit of max. operating pressure
and external pilot pressure range is 1 MPa.
Note 2) When using the VQZ100 series for a vacuum application, vacuum air
through its 1(P) port. When supplying vacuum-release air, supply it through
its 3(R) port. But do not supply vacuum-release air exceeding 50% for the
external pilot pressure.
In addition, when the VQZ100 is to be used at an operating pressure greater
than 0.2 MPa, please assure that the operating pressure is set to equal to or
less than the external pilot pressure.
External pilot
pressure range
R
Series
VQZ
Semi-standard Specifications
Base Mounted
Note 1)
CE-compliant
Nil
Q
—
CE-compliant
Nil
Q
—
CE-compliant
Nil
Q
—
CE-compliant
Nil
Q
—
CE-compliant
CE-compliant
CE-compliant
CE-compliant
[Option]
1823
SYJ
VQZ
VP
VG
VP3
VQZ