45
ø16.5
VQZ100
VQZ200
VQZ300
Dimensions
Blanking plate assembly
VVQZ100-10A-5 (for VQZ100)
VVQZ200-10A-5 (for VQZ200)
VVQZ300-10A-5 (for VQZ300)
Blanking plug
KQ2P-23
KQ2P-04
KQ2P-06
KQ2P-08
KQ2P-10
Silencer
(for manifold EXH port)
Silencer is installed in the manifold EXH port.
DIN rail
AN110-01
AN20-02
AN20-02
Silencer part no.
Model
L
A
ø
D
L
7.5
(25)
(35)
AXT100-DR-
Each manifold can be mounted on a DIN rail.
Insert “D” at the end of the manifold part number.
The DIN rail is approximately 30 mm longer than
the length of manifold.
∗
As for
, enter the number from the DIN rail dimensions table.
For L dimension, refer to the dimensions of each kit.
40
510.5
39
498
38
485.5
37
473
36
460.5
35
448
34
435.5
33
423
32
410.5
31
398
30
385.5
29
373
28
360.5
27
348
26
335.5
25
323
24
310.5
23
298
22
285.5
21
273
No.
L dimension
20
260.5
19
248
18
235.5
17
223
16
210.5
15
198
14
185.5
13
173
12
160.5
11
148
10
135.5
9
123
8
110.5
7
98
6
85.5
5
73
4
60.5
3
48
2
35.5
1
23
No.
L dimension
L Dimension
34
ø13
AN20-02
AN110-01
KQ2P-23
KQ2P-04
KQ2P-06
KQ2P-08
KQ2P-10
Dimensions
3.2
4
6
8
10
Applicable
fitting size ød
Model
16
16
18
20.5
22
31.5
32
35
39
43
5
6
8
10
12
A
L
D
(mm)
Port plug
VVQZ100-CP (for VQZ100)
This is used when changing piping location. (Side or Top)
It is used by attaching on the manifold block for being
prepared for removing a valve for maintenance reasons
or planning to mount a spare valve, etc.
Manifold Options
Series
VQZ100/200/300
1822
A