VQZ100/200
VQZ300
VVQ1000-50A-C3
—
VVQ1000-50A-C4
—
VVQ1000-50A-C6
VVQ1000-51A-C6
—
VVQ1000-51A-C8
—
VVQ1000-51A-C10
C3
C4
C6
C8
C10
Fitting size
Model
One-touch Fitting Assembly (for Cylinder port)
Note) Purchasing order is available in units of 10 pieces.
VVQ1000-50A-M5
—
M5 (VQZ100 only)
<Gasket and screw assembly>
VQZ100-GS-2
VQZ200-GS-2
VQZ300-GS-2
VQZ100
VQZ200
VQZ300
Note) The above part numbers are for 10 valves
(a set of 10 gaskets and 20 screws).
Part no.
Model
<Bracket assembly>
Part no.
VQZ100-FB
VQZ200-FB
VQZ300-FB
Model
Tightening torque (N·m)
Note)
0.25 to 0.35
VQZ100
VQZ200
VQZ300
Note) Tightening torque when mounting a bracket on
the valve.
<Plug connector assembly>
Lead wire length
Nil
300 mm
600 mm
1000 mm
1500 mm
2000 mm
2500 mm
3000 mm
5000 mm
6
10
15
20
25
30
50
SY100-30-4A-
SY100-30-1A-
SY100-30-2A-
SY100-30-3A-
SY100-30-A
DC:
100 VAC:
200 VAC:
Other AC voltages:
Without lead wire:
(with connector and 2 sockets only)
How to Order
Include the connector assembly part number together with the part
number for the plug connector’s solenoid valve without connector.
AC
VQZ115-1LO1-M5-PR
SY100-30-1A-20
DC
VQZ115-5LO1-M5-PR
SY100-30-4A-20
Example) In case of 2000 mm of lead wire
When replacing only the pilot valve assembly, use caution
because it is not possible to convert to a V115 (DIN terminal)
from a V111 (Grommet, L-type, M-type), or vice versa.
Caution
V111
<Pilot valve assembly>
5 G
Manual override
None (Applicable to VQZ200/300)
Yes (Applicable to VQZ100)
Nil
M
V115
X110
<DIN terminal type (Applicable to the VQZ200/300)>
5 Y
Function
Electrical entry
Coil voltage
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC
1
2
3
4
5
6
DIN terminal
DIN terminal without connector
DIN terminal with light/surge voltage suppressor
DIN terminal with surge voltage suppressor (DC specification)
DIN terminal with surge voltage suppressor, without connector
(DC specification)
Y
YO
YZ
YS
Note)
YOS
Note)
Light/surge
voltage
suppressor
None
Yes
Yes
(Without
light)
Electrical entry
Symbol
Note) For AC voltage valves there is no “S” type. It is already built-in to the rectifier circuit.
Electrical entry
Valve model
Pilot valve model
VQZ115
-
L
1
VQZ115
-
M
1
V111
M-
M
V111
M-
L
Note) VQZ pilot valve electrical entry (L, M) is the opposite of the how to order of valve
body.
Grommet (DC specification)
L-type plug connector with lead wire
L-type plug connector without connector
M-type plug connector with lead wire
M-type plug connector without connector
G
LU
LOU
MU
MOU
—
LZ
LOZ
MZ
MOZ
Light/surge voltage
suppressor
None
Yes
Electrical entry
Symbol
DC
AC
Coil voltage
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC
1
2
3
4
5
6
Note) Semi-standard
Standard
High speed response type
High pressure type
(Metal seal type only)
Nil
B
Note)
K
Note)
Symbol
Specifications
DC
(0.35 W)
(0.9 W)
(0.9 W)
—
—
AC
Note) Semi-standard
Function
Standard
High speed response type
(Applicable to VQZ200/300)
High pressure type (Applicable to
Metal seal type, Poppet seal type)
Nil
B
Note)
K
Note)
Symbol
Specifications
DC
(0.35 W)
(0.9 W)
(0.9 W)
—
—
AC
Manual override
(Applicable to the VQZ100)
Non-locking push type
Locking slotted type
Nil
B
Series
VQZ
Replacement Parts
Body Ported
1807
SYJ
VQZ
VP
VG
VP3
VQZ
A