1. Removing
1) Loosen the clamp screw on
the side of both ends of the
manifold.
2) Lift the side of the mani
fold off the DIN rail and slide it
in the direction of the side.
2. Mounting
1) Catch the hook of the DIN rail
bracket on the side on the
DIN rail.
2) Push side onto the DIN rail
and tighten the clamp screw.
The proper tightening torque
for screws is 0.3 to 0.4 N
m.
16
.8
13.8
2.Valve piped on top can be operated indepen-
dently by using PR plate.
(Refer to the below part numbers when placing an order.)
Precautions
The clip length for the valve and the base are different. Fitting
may detach if the incorrect clip is used.
One-touch Fittings Replacement
Caution
The built-in fittings on the manifold can be
changed easily. Simply remove the corre-
sponding valve and take out the fitting clip under-
neath.
Take out the clip with a screwdriver, etc., then replace the fittings.
About mounting the fittings, after inserting the fitting until it stops,
then put the clip into the prescribed position.
DIN Rail Removal/Mounting
Caution
VQZ200: Horizontally clipped to the valve body
VQZ100/300: Vertically clipped to the valve body
Precautions
When pulling the fitting assembly away from the valve base,
remove the clip, then connect a tube or plug (KQ2P-
) with the
One-touch fitting and pull it out holding the tube or plug. Do not
hold the release bushing to avoid damage.
Fitting assembly
Clip
Clip
Fitting assembly
Clip
Fitting assembly
Clamp bracket
Clamp screw
Valve Mounting
Caution
1. After confirming the gasket is correctly
placed under the valve, securely tighten the
bolts with the proper torque shown in the
table below.
Model
VQZ100
VQZ200
VQZ300
Proper tightening torque
0.13 to 0.19 N·m
0.25 to 0.35 N·m
0.5 to 0.7 N·m
Screw
1. How to replace the port direction
Fitting and port plug are modules. After removing the clip with
a flat head screwdriver, take out the fitting and port plug. The
piping direction (side or top) can be altered by exchanging the
fitting and port plug. During exchange, insert the fitting and the
port plug until they contact the wall, then, insert the clip to
specified position.
VQZ100 Piping Direction Replacement
Caution
Clip
Port plug
(VVQZ100-CP)
Fitting
PR plate
VQZ100-12A (Standard)
VQZ100-12B (External pilot type)
∗
2 set screws are included.
Series
VQZ
Specific Product Precautions 4
Be sure to read before handling.
Refer to front matter 53 for Safety Instructions and pages 3 to 8 for 3/4/5 Port
Solenoid Valve Precautions.
1829
SYJ
VQZ
VP
VG
VP3
VQZ