1. Precautions for system design 

     

Warning 

(1)Confirm the specifications. 

Fully understand the applications, fluids, environment and other operating conditions to use this 

product within the specified range shown in this operation manual.

 

(2)Applicable fluids 

●If the fluid contains foreign matter, the inside of the pump will become worn out , causing 

problems. Eliminate the foreign matter by using an appropriate filter (strainer).As a guide, the 

appropriate filtration is 80 to 100 mesh (150 to 180mm).

 

●When circulating coagulable fluids, handle them carefully so that they do not coagulate in the 

pump. 

●Use caution so that the operating fluid does not adhere to the product outer surface.Never use 

the product with the operating fluid adhering to the product outer surface. 

(3)Water hammer 

Sudden operation of the valve may create high pressure due to water hammer.Take measures so 

that pressure exceeding the specification value is not applied. 

<Countermeasures> 

●Reduce the opening speed of the valve by using a water hammer cushioning valve. 
●Use a material for piping such as a rubber hose or an accumulator to absorb the impact 

pressure.

   

(4)Liquid-sealed circuit

 

Mount a by-pass valve to the system so that it does not 

form a liquid-sealed circuit. (Figure on the right)   

 

(5)Fluid pressure 

Feeding the fluid from the suction side into the pump with pressure or drawing it with negative 

pressure will cause reverse pressure to be applied to the diaphragm and the check valve, causing 

shortening of the product life. 

(6)Provide enough space for maintenance.

 

Allow sufficient space for maintenance and inspection. 

(7)Provide safety measures against fluid leakage.

 

Take fluid leakage of the product into consideration when using. When transferring flammable 

fluids or fluids which affect the human body and environment, take measures such as prohibiting 

ignition sources, and prohibiting entry to the operation area. External leakage of pumping fluid 

could cause serious injury. 

(8)Design the circuit so that reverse flow and reverse pressure are prevented. 

Reverse flow or reverse pressure may lead to damage to equipment and operation failure. Take 

safety measures when designing the circuit. When installing a check valve, use the check valve 

whose cracking pressure is 0.02MPa or less. Using the check valve of higher cracking pressure, 

suction failure might be occurred. 

Countermeasure against 

liquid-sealed circuit 

Relief valve 

Pump 

Summary of Contents for PB1313A

Page 1: ...Doc no PAB OM O003 Product name Process pump Model Series PB1313A SMC Corporation Operation Manual...

Page 2: ...manual is intended to explain the installation and operation of the product Only people who understand the basic operation of the product through this manual or who perform installation and operation...

Page 3: ...stem design 6 2 Precautions for installation 7 3 Maintenance and check 9 4 Handling Precautions 10 5 Names and functions of parts 10 6 How to use 11 7 Specification and how to order 12 8 Discharge cap...

Page 4: ...ment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The as...

Page 5: ...bility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product...

Page 6: ...Read and understand the Material Safety Data Sheet MSDS carefully before using the product and use appropriate protective equipment Warning related to inhalation This symbol indicates a possible risk...

Page 7: ...sorb the impact pressure 4 Liquid sealed circuit Mount a by pass valve to the system so that it does not form a liquid sealed circuit Figure on the right 5 Fluid pressure Feeding the fluid from the su...

Page 8: ...y cannot be transferred due to seating failure and wearing of the check valve and accumulation of particles causing operation failure 2 Precautions for installation Warning 1 Use clean air 1 Do not us...

Page 9: ...not applied to the tube Caution 1 Assemble after reading the operation manual Mount the product after reading the operation manual carefully Also keep it available whenever necessary 2 Check the mount...

Page 10: ...equipment can operate normally 3 Do not disassemble the product Disassembled product is not guaranteed If overhaul is required contact SMC or the distributor 4 Discharging condensate Operation with co...

Page 11: ...ump External leakage of pumping fluid could cause serious injury 5 Countermeasures against liquid leakage There are some cases where the operating fluid will leak outside the pump for example when the...

Page 12: ...ter 3 To stop the pump stop the solenoid valve and make sure to exhaust all the air inside the pump Although the pump is stopped by closing the valve installed at the discharge side avoid stopping ope...

Page 13: ...rating fluid temperature 0 to 50 No freezing heat cycle is not applied Ambient temperature 0 to 50 No freezing heat cycle is not applied Recommended operating cycle 1 to 5Hz Pilot air solenoid valve r...

Page 14: ...e Symbol Main fluid connection size Pilot air connection size Female thread 01 Rc 1 8 N01 NPT 1 8 F01 G 1 8 Tube extension P07 With 1 4 tubing Rc 1 8 P07N NPT 1 8 P07F G 1 8 With nut 1S07 LQ1 size 2 w...

Page 15: ...specification of the device In an application where back pressure is applied from the discharge port FLUID OUT the result of pilot air pressure back pressure is the pilot air pressure on the graph Al...

Page 16: ...ove when the viscosity is 15mPa s From the graph it is approx 40 2 Next convert it to discharge rate of clean water 40 of the discharge of clean water corresponds to 200mL min of required specificatio...

Page 17: ...it Otherwise the fluid could cause burns and other injuries during transportation If the product is to be returned inform SMC or the distributor beforehand Trouble Possible cause Remedy 1 Supply of a...

Page 18: ...or replace the filter Supply air at adequate pressure Increase the air supply Remove the back pressure or increase the air supply pressure 4 A lot of air bubbles come out from the discharge side OUT...

Page 19: ...18 10 Outer dimensions...

Page 20: ...u Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer...

Reviews: