background image

 

3

 

 

 

 

     

Safety Instructions

 

 

These safety instructions are intended to prevent hazardous situations and/or equipment damage.

 

These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or 
“Danger.”

 

They are all important notes for safety and must be followed in addition to International Standards 
(ISO/IEC)

*1)

, and other safety regulations.

 

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.

 

   

ISO 4413: Hydraulic fluid power -- General rules relating to systems.

 

   

IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements)

 

   

ISO 10218-1992: Manipulating industrial robots -Safety.

                                                                                 

 

 

  etc.

 

 

     

 
 

Caution

 

Caution

 indicates a hazard with a low level of risk which, if not avoided, could result 

in minor or moderate injury.

 

 
 

Warning

 

Warning

 

indicates a hazard with a medium level of risk which, if not avoided, could 

result in death or serious injury.

 

 
 

Danger

 

Danger

 

indicates a hazard with a high level of risk which, if not avoided, will result 

in death or serious injury.

 

 

Warning

 

1.  The  compatibility  of  the  product  is  the  responsibility  of  the  person  who  designs  the 

equipment or decides its specifications.

 

Since  the  product  specified  here  is  used  under  various  operating  conditions,  its  compatibility  with  specific 
equipment must be decided by the person who designs the equipment or decides its specifications based on 
necessary analysis and test results.   
The expected performance and safety assurance of the equipment will be the responsibility of the person who 
has determined its compatibility with the product.   
This  person  should  also  continuously  review  all  specifications  of  the  product  referring  to  its  latest  catalog 
information, with a view to giving due consideration to any possibility of equipment failure when configuring the 
equipment.

 

2. Only personnel with appropriate training should operate machinery and equipment.

 

The product specified here may become unsafe if handled incorrectly.

 

The  assembly,  operation  and  maintenance  of  machines  or  equipment  including  our  products  must  be 
performed by an operator who is appropriately trained and experienced.

 

3.  Do  not  service  or  attempt  to  remove  product  and  machinery/equipment  until  safety  is 

confirmed.

 

1.The inspection and maintenance of machinery/equipment should only be performed after measures to   

prevent falling or runaway of the driven objects have been confirmed.

 

2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented 
    and the power from any appropriate source is cut, and read and understand the specific product precautions 
    of all relevant products carefully.

 

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

 

4. Contact SMC beforehand and take special consideration of safety measures if the product is 

to be used in any of the following conditions.

 

1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to 
    direct sunlight.

 

2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, 

  vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and 
  beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or 
  other applications unsuitable for the standard specifications described in the product catalog.

 

3. An application which could have negative effects on people, property, or animals requiring special safety   

analysis.

 

4.Use  in  an  interlock  circuit,  which  requires  the  provision  of  double  interlock  for  possible  failure  by  using  a 

mechanical protective function, and periodical checks to confirm proper operation. 

 

Summary of Contents for PB1313A

Page 1: ...Doc no PAB OM O003 Product name Process pump Model Series PB1313A SMC Corporation Operation Manual...

Page 2: ...manual is intended to explain the installation and operation of the product Only people who understand the basic operation of the product through this manual or who perform installation and operation...

Page 3: ...stem design 6 2 Precautions for installation 7 3 Maintenance and check 9 4 Handling Precautions 10 5 Names and functions of parts 10 6 How to use 11 7 Specification and how to order 12 8 Discharge cap...

Page 4: ...ment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The as...

Page 5: ...bility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product...

Page 6: ...Read and understand the Material Safety Data Sheet MSDS carefully before using the product and use appropriate protective equipment Warning related to inhalation This symbol indicates a possible risk...

Page 7: ...sorb the impact pressure 4 Liquid sealed circuit Mount a by pass valve to the system so that it does not form a liquid sealed circuit Figure on the right 5 Fluid pressure Feeding the fluid from the su...

Page 8: ...y cannot be transferred due to seating failure and wearing of the check valve and accumulation of particles causing operation failure 2 Precautions for installation Warning 1 Use clean air 1 Do not us...

Page 9: ...not applied to the tube Caution 1 Assemble after reading the operation manual Mount the product after reading the operation manual carefully Also keep it available whenever necessary 2 Check the mount...

Page 10: ...equipment can operate normally 3 Do not disassemble the product Disassembled product is not guaranteed If overhaul is required contact SMC or the distributor 4 Discharging condensate Operation with co...

Page 11: ...ump External leakage of pumping fluid could cause serious injury 5 Countermeasures against liquid leakage There are some cases where the operating fluid will leak outside the pump for example when the...

Page 12: ...ter 3 To stop the pump stop the solenoid valve and make sure to exhaust all the air inside the pump Although the pump is stopped by closing the valve installed at the discharge side avoid stopping ope...

Page 13: ...rating fluid temperature 0 to 50 No freezing heat cycle is not applied Ambient temperature 0 to 50 No freezing heat cycle is not applied Recommended operating cycle 1 to 5Hz Pilot air solenoid valve r...

Page 14: ...e Symbol Main fluid connection size Pilot air connection size Female thread 01 Rc 1 8 N01 NPT 1 8 F01 G 1 8 Tube extension P07 With 1 4 tubing Rc 1 8 P07N NPT 1 8 P07F G 1 8 With nut 1S07 LQ1 size 2 w...

Page 15: ...specification of the device In an application where back pressure is applied from the discharge port FLUID OUT the result of pilot air pressure back pressure is the pilot air pressure on the graph Al...

Page 16: ...ove when the viscosity is 15mPa s From the graph it is approx 40 2 Next convert it to discharge rate of clean water 40 of the discharge of clean water corresponds to 200mL min of required specificatio...

Page 17: ...it Otherwise the fluid could cause burns and other injuries during transportation If the product is to be returned inform SMC or the distributor beforehand Trouble Possible cause Remedy 1 Supply of a...

Page 18: ...or replace the filter Supply air at adequate pressure Increase the air supply Remove the back pressure or increase the air supply pressure 4 A lot of air bubbles come out from the discharge side OUT...

Page 19: ...18 10 Outer dimensions...

Page 20: ...u Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer...

Reviews: