background image

 

4

 

 

 

 

 
       

Safety Instructions

 

Caution

 

1.The product is provided for use in manufacturing industries.

 

The product herein described is basically provided for peaceful use in manufacturing industries.

 

If  considering  using  the  product  in  other  industries,  consult  SMC  beforehand  and  exchange 
specifications or a contract if necessary.

 

If anything is unclear, contact your nearest sales branch.

 

 

Limited warranty and Disclaimer/Compliance Requirements

 

The  product  used  is  subject  to the  following  “Limited  warranty  and  Disclaimer”  and  “Compliance 
Requirements”.

 

Read and accept them before using the product.

 

 

Limited warranty and Disclaimer                                                                           

 

1.  The  warranty  period  of  the  product  is  1  year  in  service  or  1.5  years  after  the  product  is 

delivered, whichever is first.

2)

   

Also,  the  product  may  have  specified  durability,  running  distance  or  replacement  parts. 
Please 
consult your nearest sales branch.

 

 

2.  For  any  failure  or  damage  reported  within  the  warranty  period  which  is  clearly  our 

responsibility, 

  a replacement product or necessary parts will be provided.

 

This limited warranty applies only to our product independently, and not to any other damage 

  incurred due to the failure of the product.

 

 

3.  Prior  to  using  SMC  products,  please  read  and  understand  the  warranty  terms  and 

disclaimers   
noted in the specified catalog for the particular products.

 

 
 

2) 

Vacuum pads are excluded from this 1 year warranty.

 

      

A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.

 

Also, even within the warranty period, the wear of a product due to the use of the vacuum 

pad or failure due to the deterioration of rubber material are not covered by the limited 

  warranty.

 

 
 

Compliance Requirements

 

1.  The  use  of  SMC  products  with  production  equipment  for  the  manufacture  of  weapons  of 

mass destruction (WMD) or any other weapon is strictly prohibited. 

2.  The exports of SMC products or technology from one country to another are governed by 

the relevant security laws and regulations of the countries involved in the transaction. Prior 
to the shipment of a SMC product to another country, assure that all local rules governing 
that export are known and followed. 

Summary of Contents for PB1313A

Page 1: ...Doc no PAB OM O003 Product name Process pump Model Series PB1313A SMC Corporation Operation Manual...

Page 2: ...manual is intended to explain the installation and operation of the product Only people who understand the basic operation of the product through this manual or who perform installation and operation...

Page 3: ...stem design 6 2 Precautions for installation 7 3 Maintenance and check 9 4 Handling Precautions 10 5 Names and functions of parts 10 6 How to use 11 7 Specification and how to order 12 8 Discharge cap...

Page 4: ...ment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The as...

Page 5: ...bility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product...

Page 6: ...Read and understand the Material Safety Data Sheet MSDS carefully before using the product and use appropriate protective equipment Warning related to inhalation This symbol indicates a possible risk...

Page 7: ...sorb the impact pressure 4 Liquid sealed circuit Mount a by pass valve to the system so that it does not form a liquid sealed circuit Figure on the right 5 Fluid pressure Feeding the fluid from the su...

Page 8: ...y cannot be transferred due to seating failure and wearing of the check valve and accumulation of particles causing operation failure 2 Precautions for installation Warning 1 Use clean air 1 Do not us...

Page 9: ...not applied to the tube Caution 1 Assemble after reading the operation manual Mount the product after reading the operation manual carefully Also keep it available whenever necessary 2 Check the mount...

Page 10: ...equipment can operate normally 3 Do not disassemble the product Disassembled product is not guaranteed If overhaul is required contact SMC or the distributor 4 Discharging condensate Operation with co...

Page 11: ...ump External leakage of pumping fluid could cause serious injury 5 Countermeasures against liquid leakage There are some cases where the operating fluid will leak outside the pump for example when the...

Page 12: ...ter 3 To stop the pump stop the solenoid valve and make sure to exhaust all the air inside the pump Although the pump is stopped by closing the valve installed at the discharge side avoid stopping ope...

Page 13: ...rating fluid temperature 0 to 50 No freezing heat cycle is not applied Ambient temperature 0 to 50 No freezing heat cycle is not applied Recommended operating cycle 1 to 5Hz Pilot air solenoid valve r...

Page 14: ...e Symbol Main fluid connection size Pilot air connection size Female thread 01 Rc 1 8 N01 NPT 1 8 F01 G 1 8 Tube extension P07 With 1 4 tubing Rc 1 8 P07N NPT 1 8 P07F G 1 8 With nut 1S07 LQ1 size 2 w...

Page 15: ...specification of the device In an application where back pressure is applied from the discharge port FLUID OUT the result of pilot air pressure back pressure is the pilot air pressure on the graph Al...

Page 16: ...ove when the viscosity is 15mPa s From the graph it is approx 40 2 Next convert it to discharge rate of clean water 40 of the discharge of clean water corresponds to 200mL min of required specificatio...

Page 17: ...it Otherwise the fluid could cause burns and other injuries during transportation If the product is to be returned inform SMC or the distributor beforehand Trouble Possible cause Remedy 1 Supply of a...

Page 18: ...or replace the filter Supply air at adequate pressure Increase the air supply Remove the back pressure or increase the air supply pressure 4 A lot of air bubbles come out from the discharge side OUT...

Page 19: ...18 10 Outer dimensions...

Page 20: ...u Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer...

Reviews: