background image

 

10

 

 

 

4. Handling Precautions 

     

Warning 

(1)Perform testing before the actual operation. 

Verify with the actual equipment used with this product. Even if the test over a short period shows 

no problem, it may cause a malfunction depending on the components of the fluid. 

(2)Storage 

When the product is stored for a long period of time after usage, remove the fluid completely from 

the pump before storage to prevent sticking and deterioration of the pump material. 

(3)When not used for extended periods of time, perform trial run before use. 

(4)Operating environment 

When dangerous fluid is used, take measures to isolate humans from the pump. External leakage 

of pumping fluid could cause serious injury. 

(5)Countermeasures against liquid leakage 

There are some cases where the operating fluid will leak outside the pump, for example when the 

diaphragm reaches the end of the life. Measures should be taken to avoid leakage, such as 

installing a drain pan, so that people and equipment will not be adversary affected. 

 

Caution 

(1)Operating temperature 

The pump can be used within the range from 0 to 50

o

C. Do not let it freeze.

 

 

 

5. Names and functions of parts 

 

 

 

 

 

 

 

 

 

 

 

Description 

Functions 

Suction port (FLUID IN) 

Sucks the fluid to be transferred. Connect suction piping. 

Discharge port (FLUID OUT) 

Discharges the fluid taken in the pump. Connect discharge piping. 

Air supply port (AIR SUP) 

Supplies air of set pressure. Connect the air piping. 

Air supply port

 

Discharge port

 

Suction port

 

Summary of Contents for PB1313A

Page 1: ...Doc no PAB OM O003 Product name Process pump Model Series PB1313A SMC Corporation Operation Manual...

Page 2: ...manual is intended to explain the installation and operation of the product Only people who understand the basic operation of the product through this manual or who perform installation and operation...

Page 3: ...stem design 6 2 Precautions for installation 7 3 Maintenance and check 9 4 Handling Precautions 10 5 Names and functions of parts 10 6 How to use 11 7 Specification and how to order 12 8 Discharge cap...

Page 4: ...ment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The as...

Page 5: ...bility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product...

Page 6: ...Read and understand the Material Safety Data Sheet MSDS carefully before using the product and use appropriate protective equipment Warning related to inhalation This symbol indicates a possible risk...

Page 7: ...sorb the impact pressure 4 Liquid sealed circuit Mount a by pass valve to the system so that it does not form a liquid sealed circuit Figure on the right 5 Fluid pressure Feeding the fluid from the su...

Page 8: ...y cannot be transferred due to seating failure and wearing of the check valve and accumulation of particles causing operation failure 2 Precautions for installation Warning 1 Use clean air 1 Do not us...

Page 9: ...not applied to the tube Caution 1 Assemble after reading the operation manual Mount the product after reading the operation manual carefully Also keep it available whenever necessary 2 Check the mount...

Page 10: ...equipment can operate normally 3 Do not disassemble the product Disassembled product is not guaranteed If overhaul is required contact SMC or the distributor 4 Discharging condensate Operation with co...

Page 11: ...ump External leakage of pumping fluid could cause serious injury 5 Countermeasures against liquid leakage There are some cases where the operating fluid will leak outside the pump for example when the...

Page 12: ...ter 3 To stop the pump stop the solenoid valve and make sure to exhaust all the air inside the pump Although the pump is stopped by closing the valve installed at the discharge side avoid stopping ope...

Page 13: ...rating fluid temperature 0 to 50 No freezing heat cycle is not applied Ambient temperature 0 to 50 No freezing heat cycle is not applied Recommended operating cycle 1 to 5Hz Pilot air solenoid valve r...

Page 14: ...e Symbol Main fluid connection size Pilot air connection size Female thread 01 Rc 1 8 N01 NPT 1 8 F01 G 1 8 Tube extension P07 With 1 4 tubing Rc 1 8 P07N NPT 1 8 P07F G 1 8 With nut 1S07 LQ1 size 2 w...

Page 15: ...specification of the device In an application where back pressure is applied from the discharge port FLUID OUT the result of pilot air pressure back pressure is the pilot air pressure on the graph Al...

Page 16: ...ove when the viscosity is 15mPa s From the graph it is approx 40 2 Next convert it to discharge rate of clean water 40 of the discharge of clean water corresponds to 200mL min of required specificatio...

Page 17: ...it Otherwise the fluid could cause burns and other injuries during transportation If the product is to be returned inform SMC or the distributor beforehand Trouble Possible cause Remedy 1 Supply of a...

Page 18: ...or replace the filter Supply air at adequate pressure Increase the air supply Remove the back pressure or increase the air supply pressure 4 A lot of air bubbles come out from the discharge side OUT...

Page 19: ...18 10 Outer dimensions...

Page 20: ...u Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer...

Reviews: