7. Specification and how to order 

 

●Specifications

 

Model 

PB1313A 

Type of operation 

Air operated type 

Port size 

Main fluid 
Suction/discharge port 

Rc,NPT,G 1/8 Female thread, 

1/4” PFA tube,   

LQ1 size 2 with nuts, LQ3 size 2 with nuts 

Pilot air 
Supply / Exhaust port 

Rc,NPT,G 1/8 Female thread 

Material 

Body wetted areas 

New PFA 

Diaphragm 

PTFE 

Check valve 

New PFA

PTFE 

Liquid contact seals 

PTFE 

Maximum discharge rate 

1000mL/min

 Note1)

 

Average discharge pressurer 

0 to 0.4MPa 

Pilot air pressure 

0.2 to 0.5MPa 

Air consumption 

15L/min(ANR) or less 

Suction head 

Up to 0.5m 

Noise 

71dB(A) or less 

Withstand pressure 

0.75MPa 

Diaphragm life (Reference) 

50 million times (One time per cycle) 

Operating fluid temperature 

0 to 50

(No freezing, heat cycle is not applied)

 

Ambient temperature 

0 to 50

(No freezing, heat cycle is not applied)

 

Recommended operating cycle 

1 to 5Hz 

Pilot air solenoid valve recommended Cv factor 

0.2

 Note2)

 

Weight 

0.3 kg 

Mounting orientation 

FLUID OUT port at top 

Maximum operating viscosity 

100mPa

Packaging environment 

Double clean packaging 

The values above are at normal temperature and with clean water. 

Note 1) When the piping length of both the suction side and the discharge side is almost 0m. 

It may not be possible to obtain the discharge in the specification depending on the piping 

conditions. With the air operated type, it may not be possible to obtain the discharge in the 

specification depending on the piping conditions for the pilot air. 

Note 2) Operation is possible with a valve with small Cv value when the operation cycle is small. 

 

 

 

 

 

 

 

Summary of Contents for PB1313A

Page 1: ...Doc no PAB OM O003 Product name Process pump Model Series PB1313A SMC Corporation Operation Manual...

Page 2: ...manual is intended to explain the installation and operation of the product Only people who understand the basic operation of the product through this manual or who perform installation and operation...

Page 3: ...stem design 6 2 Precautions for installation 7 3 Maintenance and check 9 4 Handling Precautions 10 5 Names and functions of parts 10 6 How to use 11 7 Specification and how to order 12 8 Discharge cap...

Page 4: ...ment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The as...

Page 5: ...bility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product...

Page 6: ...Read and understand the Material Safety Data Sheet MSDS carefully before using the product and use appropriate protective equipment Warning related to inhalation This symbol indicates a possible risk...

Page 7: ...sorb the impact pressure 4 Liquid sealed circuit Mount a by pass valve to the system so that it does not form a liquid sealed circuit Figure on the right 5 Fluid pressure Feeding the fluid from the su...

Page 8: ...y cannot be transferred due to seating failure and wearing of the check valve and accumulation of particles causing operation failure 2 Precautions for installation Warning 1 Use clean air 1 Do not us...

Page 9: ...not applied to the tube Caution 1 Assemble after reading the operation manual Mount the product after reading the operation manual carefully Also keep it available whenever necessary 2 Check the mount...

Page 10: ...equipment can operate normally 3 Do not disassemble the product Disassembled product is not guaranteed If overhaul is required contact SMC or the distributor 4 Discharging condensate Operation with co...

Page 11: ...ump External leakage of pumping fluid could cause serious injury 5 Countermeasures against liquid leakage There are some cases where the operating fluid will leak outside the pump for example when the...

Page 12: ...ter 3 To stop the pump stop the solenoid valve and make sure to exhaust all the air inside the pump Although the pump is stopped by closing the valve installed at the discharge side avoid stopping ope...

Page 13: ...rating fluid temperature 0 to 50 No freezing heat cycle is not applied Ambient temperature 0 to 50 No freezing heat cycle is not applied Recommended operating cycle 1 to 5Hz Pilot air solenoid valve r...

Page 14: ...e Symbol Main fluid connection size Pilot air connection size Female thread 01 Rc 1 8 N01 NPT 1 8 F01 G 1 8 Tube extension P07 With 1 4 tubing Rc 1 8 P07N NPT 1 8 P07F G 1 8 With nut 1S07 LQ1 size 2 w...

Page 15: ...specification of the device In an application where back pressure is applied from the discharge port FLUID OUT the result of pilot air pressure back pressure is the pilot air pressure on the graph Al...

Page 16: ...ove when the viscosity is 15mPa s From the graph it is approx 40 2 Next convert it to discharge rate of clean water 40 of the discharge of clean water corresponds to 200mL min of required specificatio...

Page 17: ...it Otherwise the fluid could cause burns and other injuries during transportation If the product is to be returned inform SMC or the distributor beforehand Trouble Possible cause Remedy 1 Supply of a...

Page 18: ...or replace the filter Supply air at adequate pressure Increase the air supply Remove the back pressure or increase the air supply pressure 4 A lot of air bubbles come out from the discharge side OUT...

Page 19: ...18 10 Outer dimensions...

Page 20: ...u Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer...

Reviews: