(3)Do not use in the following environments. 

1. An environment where corrosive gases, organic solvents, chemicals, or flammable fluids are present. 

2. Where the product is exposed to sea water, water, or water vapor. 

3. Where the deterioration of the resin due to ultraviolet or temperature rise is possible because of   

direct sunlight. 

4. Where a heat source is present in the surrounding environment and ventilation is poor (shield 

the heat source with an insulator). 

5. Where impact or vibration is present. 

6. Where excess humidity or dust is present. 

(4)Compressed air at low dew point 

If ultra dry air is used as pilot air, it can reduce the lubrication characteristics and affect the 

reliability (life) of the equipment. Contact SMC beforehand. 

(5)Mounting of the pump:   

Mount the pump securely with four M4 bolts. 

(6)Caution for piping of the tube 

Support the piping according to JIS B 8370 when piping the tube. Arrange the piping so that 

tension is not applied to the tube. 

 

Caution 

(1) Assemble after reading the operation manual. 

Mount the product after reading the operation manual carefully. Also keep it available whenever 

necessary. 

(2)Check the mounting direction of the product. 

Mount the product vertically so that the FLUID OUT port faces upward. Otherwise internal parts 

will not operate smoothly to achieve the full performance. 

Secure all mounting parts properly. If the transmission of vibration is unacceptable, insert an 

isolating rubber material before installation. 

(3)Flush the piping before installing. 

Flush and clean the piping before installing the product. Dust and foreign matter left in the piping 

can cause operating failure and malfunction. 

(4)If fittings with metal threads are used, it could break the female thread of the product. For 

piping the tube fitting, use fittings with resin threads. 

(5)Observe the tightening torque for screws. 

When screwing fittings into the product, tighten them with proper tightening torque as shown 

below. Over-tightening can damage the thread. 

PB1313A series 

Thread size

 

Proper tightening torque

 

Rc,NPT,G 1/8 

1.5 to 2.0 N・m

 

 

M10 

0.8 to 1.0N・m 

Summary of Contents for PB1313A

Page 1: ...Doc no PAB OM O003 Product name Process pump Model Series PB1313A SMC Corporation Operation Manual...

Page 2: ...manual is intended to explain the installation and operation of the product Only people who understand the basic operation of the product through this manual or who perform installation and operation...

Page 3: ...stem design 6 2 Precautions for installation 7 3 Maintenance and check 9 4 Handling Precautions 10 5 Names and functions of parts 10 6 How to use 11 7 Specification and how to order 12 8 Discharge cap...

Page 4: ...ment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The as...

Page 5: ...bility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product...

Page 6: ...Read and understand the Material Safety Data Sheet MSDS carefully before using the product and use appropriate protective equipment Warning related to inhalation This symbol indicates a possible risk...

Page 7: ...sorb the impact pressure 4 Liquid sealed circuit Mount a by pass valve to the system so that it does not form a liquid sealed circuit Figure on the right 5 Fluid pressure Feeding the fluid from the su...

Page 8: ...y cannot be transferred due to seating failure and wearing of the check valve and accumulation of particles causing operation failure 2 Precautions for installation Warning 1 Use clean air 1 Do not us...

Page 9: ...not applied to the tube Caution 1 Assemble after reading the operation manual Mount the product after reading the operation manual carefully Also keep it available whenever necessary 2 Check the mount...

Page 10: ...equipment can operate normally 3 Do not disassemble the product Disassembled product is not guaranteed If overhaul is required contact SMC or the distributor 4 Discharging condensate Operation with co...

Page 11: ...ump External leakage of pumping fluid could cause serious injury 5 Countermeasures against liquid leakage There are some cases where the operating fluid will leak outside the pump for example when the...

Page 12: ...ter 3 To stop the pump stop the solenoid valve and make sure to exhaust all the air inside the pump Although the pump is stopped by closing the valve installed at the discharge side avoid stopping ope...

Page 13: ...rating fluid temperature 0 to 50 No freezing heat cycle is not applied Ambient temperature 0 to 50 No freezing heat cycle is not applied Recommended operating cycle 1 to 5Hz Pilot air solenoid valve r...

Page 14: ...e Symbol Main fluid connection size Pilot air connection size Female thread 01 Rc 1 8 N01 NPT 1 8 F01 G 1 8 Tube extension P07 With 1 4 tubing Rc 1 8 P07N NPT 1 8 P07F G 1 8 With nut 1S07 LQ1 size 2 w...

Page 15: ...specification of the device In an application where back pressure is applied from the discharge port FLUID OUT the result of pilot air pressure back pressure is the pilot air pressure on the graph Al...

Page 16: ...ove when the viscosity is 15mPa s From the graph it is approx 40 2 Next convert it to discharge rate of clean water 40 of the discharge of clean water corresponds to 200mL min of required specificatio...

Page 17: ...it Otherwise the fluid could cause burns and other injuries during transportation If the product is to be returned inform SMC or the distributor beforehand Trouble Possible cause Remedy 1 Supply of a...

Page 18: ...or replace the filter Supply air at adequate pressure Increase the air supply Remove the back pressure or increase the air supply pressure 4 A lot of air bubbles come out from the discharge side OUT...

Page 19: ...18 10 Outer dimensions...