background image

 

 
 

Safety Instructions

 

 

Caution

 

1.The product is provided for use in manufacturing industries.

 

The product herein described is basically provided for peaceful use in manufacturing industries.

 

If  considering  using  the  product  in  other  industries,  consult  SMC  beforehand  and  exchange 
specifications or a contract if necessary.

 

If anything is unclear, contact your nearest sales branch.

 

 

Limited warranty and Disclaimer/Compliance Requirements

 

The product used is subject to the following “Limited warranty and Disclaimer” and “Compliance 
Requirements”.

 

Read and accept them before using the product.

 

 

Limited warranty and Disclaimer                                                                           

 

1.  The  warranty  period  of  the  product  is  1  year  in  service  or  1.5  years  after  the  product  is 

delivered, whichever is first.

2) 

Also,  the  product  may  have  specified  durability,  running  distance  or  replacement  parts. 
Pleaseconsult your nearest sales branch.

 

2.  For  any  failure  or  damage  reported  within  the  warranty  period  which  is  clearly  our 

responsibility, a replacement product or necessary parts will be provided.

 

This limited warranty applies only to our product independently, and not to any other damage   

  incurred due to the failure of the product.

 

3.  Prior  to  using  SMC  products,  please  read  and  understand  the  warranty  terms  and 

disclaimers noted in the specified catalog for the particular products.

 

 

2) 

Vacuum pads are excluded from this 1 year warranty.

 

      

A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.

 

Also, even within the warranty period, the wear of a product due to the use of the vacuum 

pad or failure due to the deterioration of rubber material are not covered by the limited 

  warranty.

 

 

Compliance Requirements

 

1.  The  use  of  SMC  products  with  production  equipment  for  the  manufacture  of  weapons  of 

mass destruction(WMD) or any other weapon is strictly prohibited. 

2. The exports of SMC products or technology from one country to another are governed by the 

relevant security laws and regulation of the countries involved in the transaction. Prior to the 
shipment  of  a  SMC  product  to  another  country,  assure  that  all  local  rules  governing  that 
export are known and followed. 

 

Return of Product 

If the product to be returned is contaminated or is possibly contaminated with substances that 
are harmful to humans, for safety reasons, please contact SMC beforehand and then employ a 
specialist  cleaning  company  to  decontaminate  the  product.  After  the  decontamination 
prescribed  above  has  been  carried  out,  submit  a  Product  Return  Request  Sheet  or  the 
Detoxification/Decontamination  Certificate  to  SMC  and  await  SMC’s  approval  and  further 
instructions before attempting to return the item. 
Please refer to the International Chemical Safety Cards (ICSC) for a list of harmful substances. 
If  you  have  any  further  questions,  please  don’t  hesitate  to  contact  your  SMC  sales 
representative. 

 

Summary of Contents for PAF3410

Page 1: ...Doc no PAB OM H007 D PRODUCT NAME Process Pump MODEL Series Product Number PAF3410...

Page 2: ...scription and function of individual port P 5 4 How to use P 5 to 6 5 Maintenance and check P 6 6 Specification and how to order P 7 to 8 7 Discharge capability P 9 to 10 8 Troubleshooting P 11 to 12...

Page 3: ...ent failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The ass...

Page 4: ...ts 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product...

Page 5: ...frigerating air dryer AM mist separator AMD micro mist separator PAF If the amount of foreign materials generated from air supply carbon powder etc is large mount super mist separator etc to reinforce...

Page 6: ...of individual port Suction port FLUID IN To suck transported fluid Connect suction piping Discharge port FLUID OUT To discharge fluid sucked inside the pump Connect discharge piping Air supply port A...

Page 7: ...dically If any abnormality or concern is seen stop the pump immediately and contact local supplier or SMC When touching the pump for maintenance put the protective tool such as glove which isn t affec...

Page 8: ...ir Supply Exhaust port Rc G NPT 1 4 Material Body wetted areas newPFA Diaphragm Seal PTFE Check valve newPFA PTFE Discharge flow rate 1 to 20L min Average discharge pressure 0 to 0 4MPa Air consumptio...

Page 9: ...ng type Fitting size In side Out side Symbol Thread style Symbol Style NIL Fitting type With silencer Operation type Tube port Female thread Option Thread style NIL Port size Tube size Thread style NI...

Page 10: ...sh water viscosity 1mPa s specific gravity 1 0 Thus if the fluid with higher viscosity such as oil is used convert the fluid to fresh water with reference to viscosity characteristic graph The dischar...

Page 11: ...ge rate of fresh water Since discharge rate 45 of fresh water is equal to 4 5L min of the fluid with the following calculation 4 5L min 0 45 10L min It is found discharge rate 10L min is necessary for...

Page 12: ...ement of pilot air switching part Review of piping at suction or discharge side and removal of restrictor Replacement of pump Supply of air at adequate pressure Cleaning Replacement of pump 2 The pump...

Page 13: ...placement Supply of air at adequate pressure Increase of air supply Removal of back pressure or increase of supplied air pressure 4 A lot of air bubble come out from discharge side FLUID OUT Air is su...

Page 14: ...ntrol valve is shifted and starts reverse operation Fig 2 This repeated operation realizes continuous suction and discharge Air exhaust port AIR EXH Air supply port AIR SUP Discharge port FLUID OUT Su...

Page 15: ...th the round head Philips screws tightening torque 0 125N m Fig 2 3 Insert optical fibers to the amplifier and set the amplifier to Percent tuning At this time the ratio at the threshold level is set...

Page 16: ...r of amp for the sensor 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice...