RLMPFV12 12 Volt Multipurpose Transfer Pump

English

EN

OWNER'S MANUAL

The RLMPFV12 portable utility transfer pump is intended for intermittent duty, moving water from one location 
to another. This pump may be used for transferring liquids and emptying or filling tanks, sinks or bowls. It can be 
used to pump bilge water, but must not be located in the bilge area. It is self-priming to 6 ft. if the impeller is ini

-

tially wet (primed). A carrying handle is included.
This pump is intended for open air use and intermittent use only. Do not run the pump for 
more than 15 minutes per hour.
Do NOT use this pump for:

Submersible applications—submersion will immediately damage the pump

Transferring potable water

Effluent or sewage applications

As a pond pump, or for pumping seawater

Water hotter than 77°F (25°C) or colder than 32°F (0°C)

Pumping soap detergents

Locations classified as hazardous according to the National Electrical
Code (ANSI/NFPA)

Please examine your pump carefully to ensure that no damage occurred during shipment. 
If damage has occurred, please contact the place of purchase. They will assist you in replacement or repair, if 
required. 
This product is covered by a Limited Warranty for a period of 12 months from the date of original purchase by the 
consumer. This Warranty DOES NOT apply to flex-vane impellers, or cam. For complete warranty information, 
refer to 

www.redlionproducts.com

; or, call Technical Support for a printed copy.

Specifications

Model

Phase

Volts

Amps

Watts

HP

Shut Off

RLMPFV12

1

12 VDC

9

110

1/12

38 ft (11.6 m)

BEFORE GETTING STARTED

This equipment should be installed and serviced by technically 
qualified personnel who are familiar with the correct selection 
and use of appropriate tools, equipment, and procedures. Failure 
to comply with national and local electrical and plumbing codes 
and within Red Lion recommendations may result in electrical 
shock or fire hazard, unsatisfactory performance, or equipment 
failure.
Know the product’s application, limitations, and potential haz

-

ards. Read and follow instructions carefully to avoid injury and 
property damage. Do not disassemble or repair unit unless 
described in this manual.
Refer to product data plate(s) for additional precautions, operat

-

ing instructions and specifications.

Failure to follow installation or operation procedures and all 
applicable codes may result in the following hazards:

Risk of death, personal injury, or property 

damage due to explosion or fire.

Do not use to pump flammable or explosive fluids such as gaso

-

line, fuel oil, kerosene, etc.

Do not use in explosive atmospheres or hazardous locations as 
classified by the NEC, ANSI/NFPA70.

Batteries emit hydrogen gas that is explosive. Avoid smoking, 
sparks or open flame anywhere in the vicinity of the battery.

An explosion from the battery can cause blindness. Shield your 
eyes when working near any battery.

Batteries contain sulfuric acid. In case of contact with eyes, skin, 
or clothing flush immediately with large amounts of water and
seek medical attention. 

Summary of Contents for RLMPFV12

Page 1: ...Technical Support for a printed copy Specifications Model Phase Volts Amps Watts HP Shut Off RLMPFV12 1 12 VDC 9 110 1 12 38 ft 11 6 m BEFORE GETTING STARTED This equipment should be installed and serviced by technically qualified personnel who are familiar with the correct selection and use of appropriate tools equipment and procedures Failure to comply with national and local electrical and plum...

Page 2: ...ally wet locations Do not oil the motor The pump s motor housing is sealed Use of oil could cause permanent damage to the pump Protect lead wires from sharp objects hot surfaces oil and chemicals Avoid kinking the lead wires Replace or repair dam aged or worn lead wires immediately Do not use the lead wires for lifting the pump Do not let the unit freeze Freezing may cause cracking or distor tion ...

Page 3: ...loose or leaking hoses Any problems should be corrected before pump is returned to service Only qualified electricians or servicemen should attempt to repair this unit Impeller Replacement 1 Remove cover plate mounting screws 2 Remove cover plate and cover plate gasket 3 Slide damaged or worn impeller off motor shaft 4 Clean the inside of the pump head and the cover gasket sealing surface Make cer...

Page 4: ...res Defective motor Replace pump Pump will not prime or loses prime Air leak in suction line Locate and eliminate air leak in suction line Suction lift is too high Reduce the pump height to water source Damaged impeller Replace impeller Refer to Maintenance on page 3 Pump runs but does not dis charge fluid Damaged impeller Replace impeller Refer to Maintenance on page 3 Suction lift is too high Re...

Page 5: ...mmuniquer avec le soutien technique pour en obtenir une copie imprimée Spécifications Modèle Phase Volts Ampères Watts HP Arrêt RLMPFV12 1 12 V CC 9 110 1 12 11 6 m 38 pi AVANT DE COMMENCER Cet équipement doit être installé et entretenu par des techniciens qualifiés capables de choisir et d utiliser les outils les équipements et les procédures appropriés Le non respect des codes électriques et cod...

Page 6: ...it en contact avec de l eau Cette pompe n est pas destinée à être utilisée dans les douches les spas les cales ou d autres emplacements potentiellement mouillés Ne pas graisser le moteur Le carter moteur de la pompe est scellé L utilisation d huiles peut causer des dommages permanents de la pompe N utilisez pas les fils conducteurs pour soulever la pompe Ne laissez pas l unité geler Le gel peut ca...

Page 7: ...esserrées de mauvais alignement de la turbine de pièces fissurées ou cassées de fils conducteurs endommagés ou de tuyaux souples desserrés ou fuyants Toute anormalité doit être corrigée avant que la pompe ne soit remise en service Seuls des électriciens ou des réparateurs qualifiés devraient réparer cet appareil Remplacement de la turbine 1 Retirez les vis de fixation du couvercle 2 Retirez le cou...

Page 8: ...de la batterie Les pinces crocodiles sont corrodées Nettoyez les pinces sur les fils conducteurs Le moteur est défectueux Remplacer la pompe La pompe ne s amorce pas ou perd son amorçage Il y a une fuite d air dans la conduite d aspi ration Localiser et éliminer la fuite d air dans la conduite d aspiration La hauteur d aspiration est trop grande Réduisez la hauteur de la pompe par rapport à la sou...

Page 9: ...o bien llame al departamento de Soporte técnico para obtener una copia impresa Especificaciones Modelo Fase Voltios A Vatios HP Apagado RLMPFV12 1 12 VCC 9 110 1 12 38 pies 11 6 m ANTES DE EMPEZAR La instalación y el mantenimiento de este equipo deben estar a cargo de personal con capacitación técnica El hecho de no cum plir con los códigos eléctricos nacionales y locales y con las recomendaciones...

Page 10: ...aceites puede provocar daños permanentes a la bomba Proteja los cables conductores de objetos afilados superficies calientes aceite y productos químicos Evite torcer los cables conductores Reemplace o repare de inmediato los cables con ductores dañados o desgastados No use los cables conductores para levantar la bomba No deje que la unidad se congele La congelación puede causar agrietamiento o dis...

Page 11: ...cio Solo electricistas o técnicos de servicio calificados pueden intentar reparar esta unidad Reemplazo del impulsor 1 Retire los tornillos de montaje de la cubierta protectora 2 Retire la cubierta protectora y la junta de la cubierta 3 Deslice el impulsor dañado o desgastado fuera del eje del motor 4 Limpie el interior del cabezal de la bomba y la superficie de sellado de la junta de la cubierta ...

Page 12: ...e aire en la línea de succión Ubique y elimine la fuga de aire en la línea de succión La altura de succión es demasiado alta Reduzca la altura de la bomba con respecto a la fuente de agua Impulsor dañado Reemplace el impulsor La bomba fun ciona peronodes carga líquido Impulsor dañado Reemplace el impulsor La altura de succión es demasiado alta Reduzca la altura de la bomba con respecto a la fuente...