Operation
When the pressure level exceeds the set value, the switch turns
ON.
When the pressure level decreases only the hysteresis from the
set value, the switch turns OFF.
With the factory default settings, when the pressure level ex-
ceeds 0.35 MPa, the switch turns ON. When the pressure level
becomes 0.34 MPa or less, the switch turns OFF.
When the operation shown in the Fig. below has no problem, use
the product with the factory default settings.
For details about how to set the pressure in window comparator
mode, refer to “Pressure Setting (Window comparator mode)” on
page 339.
<Operating procedure>
About measurement mode
In this measurement mode, the pressure is detected and displayed
or the switch is operated after the power has been turned ON.
The measurement mode is a basic mode that allows you to change
the setting or set other functions according to the purpose.
Pressure Setting
Function Settings
Air-blow Module
Series
LLB1
or
Displayes
in turn.
1 second
1 second
switch ON
switch OFF
0.35
0.34
Time [second]
z
Press the button in the measurement mode
to display the set value.
x
Press the or button to change the set value.
Pressing the button will increase the set value while press-
ing the button will decrease the set value.
¡
Press the button once to increase the numeric value. Keep
the button pressed to continuously increase the numeric
value.
¡
Press the button once to decrease the numeric value. Keep
the button pressed to continuously decrease the numeric
value.
c
Press the button to complete the setting.
Switch output
Whether or not the switch output is used can be selected.
The product can be used as pressure gauge without using
the switch output.
Switch output
→
P.338
Display color
The display color can be selected.
Display color
→
P.338
Response time
When the response time is set, this prevents chattering
output.
Response time
→
P.338
Operation mode
The switch operation mode can be selected.
Operation mode
→
P.338
Hysteresis
Hysteresis
→
P.339
ON
ON: Green
OFF: Red
1s
0.01 MPa
(1psi)
Hysteresis
mode
Setting item
Factory default settings
The numeric value in ( ) shows the value when the unit specifications are P.
Output mode
The switch output mode can be set.
Output modes
→
P.339
Power-saving mode
Power-saving mode can be selected.
Power-saving mode
→
P.339
Security code setting
It can be set whether code number input is required or not
when key is locked
Security code setting
→
P.340
Normally
Open
OFF
OFF
Setting item
Factory default settings
Flip display mode
The display can be flipped vertically.
Display mode
→
P.340
Setting item
Factory default settings
The factory default settings are as follows.
When there is no problem with the factory default settings, use
the product as it is. To change any setting, make the setting
properly while referring to relevant page.
Special function settings
Handling precautions
· When changing the factory default settings, the setting item is
changed with the button. Be sure to check that the item
you want to change is displayed, and then make the setting
without fail.
Unit specifications: M
Unit specifications: P
Unit specifications: Nil
The operation enters the measurement mode and
the current pressure value is displayed.
The display that shows the unit specifications is lit for approx. 1 second.
Turn ON the power.
Pressure
[MPa]