Adapter
Lock pin
Mounting screw
O-ring
Switch body
Digital pressure switch
NPN open collector output
Max. 30 V, 80 mA
Residual voltage: 1 V or less
PNP open collector
Max. 80 mA
Residual voltage: 1 V or less
+
–
+
–
12 to 24 VDC
Load
Brown DC (+)
Black OUT
Blue DC (–)
Brown DC (+)
Black OUT
Blue DC (–)
Load
12 to 24 VDC
Main circuit
Main circuit
ISE35
Electrical entry specifications
Semi-standard
specifications
Symbol
Nil
X501
Contents
None
Oil-free
Note) Adapter, O-ring, and lock pin mounting
screws (2 pcs.) are included.
Option 2
Symbol
Nil
B
Note)
Contents
Switch body only
With mounting option
Option 1
Contents
Without lead wire with connector
With lead wire with connector (2 m)
Symbol
Nil
L
N
X501
25
Output specifications
Symbol
25
65
Contents
NPN output
PNP output
R: Wiring top entry
N: Wiring bottom entry
For details about setting and operating procedures, refer to pages 337 to 341.
0 to 1 MPa
– 0.1 to 1 MPa
1.5 MPa
0.01 MPa
12 to 24 VDC, Ripple (p-p)
±
10% or less
(with power supply polarity protection)
55 mA or less (at no load)
NPN or PNP open collector 1 output
80 mA
30 V (at NPN output)
1 V or less (with load current of 80 mA)
1s
(0.25, 0.5, 2, 3)
With short-circuit protection
±
1%F.S. or less
Variable (0 or above)
3-digit, 7-segment indicator, 2-color display (Red/Green)
can be interlocked with the switch output
±
2%F.S.
±
1digit (at 25
°
C
±
3
°
C)
OUT: Lights up when output is turned ON (Green)
IP40
ø3.4 3 cores 25AWG 2 m
Rated pressure range
Set pressure range
Withstand pressure
Set pressure resolution
Power supply voltage
Current consumption
Switch output
Repeatability
Hysteresis
Display
Display accuracy
Indicator light
Environmental
resistance
Lead wire with connector
Maximum load current
Maximum applied voltage
Residual voltage
Response time
Anti-chattering function
Short circuit protection
Hysteresis mode
Window comparator mode
Enclosure
Specifications
Model
Output specifications
M
Unit specifications
Symbol
M
Contents
Fixed SI unit
28
13
15
27
1.5
13.2
8.5
Series
LLB1
336