Pressure Setting (Window comparator mode)
z
Press the button in the measurement
mode to display the set value.
x
Press the or button to change the set value.
Pressing the button will increase the set value while pressing
the button will decrease the set value.
¡
Press the button once to increase the numeric value.
Keep the button pressed to continuously increase the
numeric value.
¡
Press the button once to decrease the numeric value.
Keep the button pressed to continuously decrease the
numeric value.
c
Press the button to display the set value at the 2nd lo-
cation.
v
Press the or button to change the set value.
b
Press the button to complete the setting.
z
Keep the button pressed for 2 seconds or
longer in the measurement mode.
When “S ” is displayed, press the button
five times. “oU ” and current set value are dis-
played alternately.
x
Press the or button to select an output mode you want
to use.
c
After selected, keep the button pressed for 2 seconds or
longer. The setting is then completed to return to the measure-
ment mode.
<Operating procedure>
<Operating procedure>
5. Hysteresis (H)
A hysteresis can be set.
z
Keep the button pressed for 2 seconds or
longer in the measurement mode.
When “S ” is displayed, press the button
four times. “ H” and current set value are
displayed alternately.
x
Press the or button to set a hysteresis you want to
use.
¡
Press the button once to increase the numeric value.
Keep the button pressed to continuously increase the
numeric value.
¡
Press the button once to decrease the numeric value.
Keep the button pressed to continuously decrease the
numeric value.
c
After selected, keep the button pressed for 2 seconds or
longer. The setting is then completed to return to the measure-
ment mode.
<Operating procedure>
7. Power-saving mode (Po )
When the power-saving mode is selected, the numeric value
display disappears to reduce the current consumption.
When any key is operated in the power-saving mode, the display
changes to the normal display. When no key is operated for 30
seconds, the display returns to the power-saving mode.
(Measurement mode only)
z
Keep the button pressed for 2 seconds or
longer in the measurement mode.
When “S ” is displayed, press the button six
times. “Po ” and current set value are dis-
played alternately.
x
Press the or button to select whether or not the power-
saving mode is used.
c
After selected, keep the button pressed for 2 seconds or
longer. The setting is then completed to return to the measure-
ment mode.
<Operating procedure>
For details about operation in the normally open or normally
close mode, refer to “List of output modes” on page 340.
Function Settings
Air-blow Module
Series
LLB1
or
Displayed alternately.
Displayed alternately.
or
Displayed alternately.
Displayed alternately.
or
or
Normally Close
(N.C.)
Normally Open
(N.O.)
Displayed alternately.
or
or
Power-saving mode
(Power-saving mode ON)
Normal display
(Power-saving mode OFF)
In the power-saving mode, the
display becomes that shown in
the Fig. on the right.
Displayed alternately.
6. Output mode (oU )
A desired switch output mode can be set.
339
HAA
HAW
AT
IDF
IDU
IDFA
IDFB
IDH
ID
IDG
IDK
AMG
AFF
AM
AMD
AMH
AME
AMF
ZFC
SF
SFD
LLB
AD
GD
LLB