![SMC Networks ITV2050-IL20-X399 Series Operation Manual Download Page 24](http://html1.mh-extra.com/html/smc-networks/itv2050-il20-x399-series/itv2050-il20-x399-series_operation-manual_1299596024.webp)
- 23 -
Operation Mode / Standby Mode setting
Operation mode set pressure, standby mode set pressure setting method
No
Key operation
LED Display
(1)
Deactivate the key lock if necessary (see page 22).
(2)
Press S-key
(3)
Set Operation Mode (PS1) set pressure
by using the
△
and
▽
keys.
⇔
(displayed alternately)
*Adjusting range: Refer to note 1 to 3
(4)
Press S-key
(5)
Set Standby Mode (PS2) set pressure by
using the
△
and
▽
keys.
⇔
(displayed alternately)
*Adjusting range: Refer to note 1 to 3
(6)
Press S-key
Display current pressure
(7)
Activate the key lock if necessary (see page 22).
(Note1)
:
Pressure can be adjusted from 0 to 700[kPa].
(Note2)
:
The adjustable range is 0 to 700[kPa], but the setting range is 0 to 1050[kPa].
(Note3)
:
The setting range of the LED display changes depending on the pressure display unit.