Product individual parameters
Index
(decimal
number)
Subindex
Access
*1
Parameter
name
Data
type
*2
Initial
value
Data
storage
*3
Details
0x40
(64)
0
R/W
Pressure
display unit
U8
{0}
Y
Setting value of pressure
display unit
0x41
(65)
0
R/W
Hold/clear
U8
{1}
Y
Pressure control setting when an
IO-Link communication error
occurs.
When {0} is set, output pressure
is cleared. When {1} is set,
output pressure is held.
0x42
(66)
0
R/W
Gain
U8
{9}
Y
The gain for the
electro-pneumatic regulator can
be adjusted in the range from 0
to 15.
0x43
(67)
0
R/W
Sensitivity
U8
{2}
Y
The sensitivity of the
electro-pneumatic regulator can
be adjusted in the range from 0
to 7.
0x48
(72)
0
R
Accumulated
energizing time
U32
{0}
Y
Displays accumulated
energizing time.
0x49
(73)
0
R/W
Notification
setting of the
accumulated
energizing time
U32
{0}
Y
Set notification of the
accumulated energizing time.
0xA0
(160)
0
R
Product number STR64
{Product
number}
N
Displays the product number.
0x4A
(74)
0
R/W
Operation
Mode (PS1)
U16
{0}
Y
Operation mode command
pressure PS1
Set pressure 0 to 1050 (fixed
kPa)
0x4B
(75)
0
R/W
Standby
mode (PS2)
U16
{0}
Y
Standby mode command
pressure PS2
Set pressure 0 to 1050 (fixed
kPa)
0x4D
(77)
0
R/W
Solenoid Valve
Stop Time
U8
{0}
Y
Setting Solenoid Valve Stop
Time
Setting range0
~
99
(%)
0x52
(82)
0
R/W
Pressure Ramp
Up Duration
U16
{0}
Y
Setting the Pressure Ramp Up
Duration
Setting range 0
~
1500
(
0.1
second unit)
*1: R means Read and W means Write.
*2: Refer to the table below for the symbol.