- 17 -
Parameter index
0x43
Parameter name
Sensitivity tuning function
Function
Changing the sensitivity will change the pressure correction operation near
the set pressure point. When the sensitivity is increased, hunting may occur.
When the sensitivity is decreased, hunting will be reduced, but the pressure
correction will be reduced, so there may be a moderate pressure instability.
Default value
:
Sensitivity
0
Bit
Bit 2, 1, 0
Value
Bit
2
1
0
Setting
0
0
0
Sensitivity -
0
0
1
Sensitivity
⁻
0
1
0
Sensitivity 0
0
1
1
Sensitivity 1
1
0
0
Sensitivity 2
1
0
1
Sensitivity 3
1
1
0
Sensitivity 4
1
1
1
Sensitivity 5
* indicates the initial shipping value.
Parameter index
0x48 (energizing time)
Parameter name
Energizing time
Function
Displays the accumulated energizing time of the electro pneumatic regulator.
Please note that the number indicates hours and is refreshed every hour.
Bit
Bit 31 to 0
Value
If the Bit are 1111 1111 1111 1111 1111 1111 1111 1111, this indicates
approximately 4 billion hours.
* Default value is 0.
*