background image

Document  :

  DIY-60K00-OM002 

 
 

 

 
 

 

 

 
 

PRODUCT NAME

 

Standby  E/P  Regulator

 

(Air Management System/ELECTRO-PNEUMATIC 

REGULATOR) 

   

 

MODEL / Series / Product Number

 

 

ITV2050-IL20-

-

-X399 

ITV2050-IL30-

-

-X399 

ITV3050-IL40-

-

-X399 

ITV3050-IL60-

-

-X399

 

 
 
 
 
 
 
 
 
 

 

Summary of Contents for ITV2050-IL20-X399 Series

Page 1: ...ent DIY 60K00 OM002 PRODUCT NAME Standby E P Regulator Air Management System ELECTRO PNEUMATIC REGULATOR MODEL Series Product Number ITV2050 IL20 X399 ITV2050 IL30 X399 ITV3050 IL40 X399 ITV3050 IL60...

Page 2: ...ey locking function P22 Operation Mode Standby Mode setting P23 Reset function P24 Error indicating function P25 Detail setting mode P26 Gain setting P27 Sensitivity setting P28 Zero clear P29 Pressur...

Page 3: ...o any possibility of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if...

Page 4: ...failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded...

Page 5: ...low out If supply pressure to this product is interrupted or shut off while the power is still on the internal solenoid valve will continue to operate and a humming noise will be generated Since it ma...

Page 6: ...ling this product and its wiring away from strong electric fields such as those of motors and power cables etc 3 Be sure to implement protective measures against load surge for inductive loads solenoi...

Page 7: ...storage function The data storage function stores the IO Link device parameter settings to the IO Link master With the IO Link data storage function the IO link device can be replaced easily without...

Page 8: ...nd device Process data consists of PD_IN process data input 4 BYTE and PD_OUT process data output 2 BYTE as shown below The process data of this product is Big Endian type When the transmission method...

Page 9: ...ernal communication error 0x1813 Occurs when an internal communication error Bit 10 Alarm generation Bit 8 9 of Byte 4 and Bit 7 4 of Byte 5 It is set when any of them is ON otherwise it is 0 Bit 9 Ex...

Page 10: ...rdless of the state of operation standby pressure ramp up duration and pressure control is forcibly stopped If the Pressure Ramp Up Duration is not reached or returns from Low False to High True durin...

Page 11: ...20 0 R Product Text N AMS ITV 0x0015 21 0 R Serial Number N xxxxxxxx 3 0x0016 22 0 R Hardware Revision N HW Vx y 4 0x0017 23 0 R Software Revision N FW Vx y 4 0x0018 24 0 R W Application Specific Tag...

Page 12: ...vailable 2 Not supported 3 1 Key locked It is linked with the key lock of button operation 0 Key lock de activated It is linked with the key lock of button operation 4 15 Not supported Command decimal...

Page 13: ...ck the functionality Not supported 4 Failure Abnormal Device details status parameter Index 0x25 Event details of the readable device status are as follows Subindex Event Event class Event code Defini...

Page 14: ...nge from 0 to 7 0x48 72 0 R Accumulated energizing time U32 0 Y Displays accumulated energizing time 0x49 73 0 R W Notification setting of the accumulated energizing time U32 0 Y Set notification of t...

Page 15: ...duct switches the switching flag on the process data using the set value INDEX 0x4A of operation mode PS1 and the set value INDEX 0x4B of standby mode PS2 It will adjust the pressure Values outside th...

Page 16: ...id or all units are valid ITV 050 IL 0 K X399 Valid for all units ITV 050 IL 0 M X399 Valid for SI units only Bit Bit 3 Value ITV 050 IL N K X399 Bit ITV 050 IL N M X399 Bit Value Unit 0 MPa 1 kPa 2 b...

Page 17: ...function Function The response time can be changed by tuning the gain When the gain is increased the response time tends to be faster but stability will be lost which may cause hunting unstable pressu...

Page 18: ...ty 0 Bit Bit 2 1 0 Value Bit 2 1 0 Setting 0 0 0 Sensitivity 0 0 1 Sensitivity 0 1 0 Sensitivity 0 0 1 1 Sensitivity 1 1 0 0 Sensitivity 2 1 0 1 Sensitivity 3 1 1 0 Sensitivity 4 1 1 1 Sensitivity 5 i...

Page 19: ...enabled Bit Bit 31 to 0 0 Value Setting the Bit to 1111 1111 1111 1111 1111 1111 1111 1111 sets it to approximately 4 billion hours Setting the Bit to 0000 0000 0000 0000 0010 0010 0011 1000 sets it...

Page 20: ...the display unit indicates the initial shipping value In addition the program can be set up to 0 41A 1050kPa Parameter 0x4B Parameter Standby Mode PS2 Function When the process data output switching f...

Page 21: ...tial value is 0 and is disabled Parameter index 0x52 Parameter name Pressure Ramp Up Duration setting Function This function gradually changes the command value in the set time when shifting from powe...

Page 22: ...essure equal to the supply pressure minus 0 1 MPa will be output 4 Output pressure from this product and state of operation are changed by changing of each setting and function Each setting and functi...

Page 23: ...y and the settings via IO Link are processed exclusively Unlocking the keys No Key operation LED Display 1 current pressure is displayed 2 Press key for 2 seconds or more is displayed 3 flashes on the...

Page 24: ...ely Adjusting range Refer to note 1 to 3 4 Press S key 5 Set Standby Mode PS2 set pressure by using the and keys displayed alternately Adjusting range Refer to note 1 to 3 6 Press S key Display curren...

Page 25: ...necessary see page 22 2 Press the and keys simultaneously for 3 seconds or more current pressure is displayed 3 is displayed for approx 1 second 4 The settings are reset and returned to the condition...

Page 26: ...o not operate normally after initialize Reading and writing errors occurred in memory Please contact us when ITV do not operate normally after restarting the power supply Solenoid valve error Solenoid...

Page 27: ...ately key key Press S key key To ZERO CLEAR refer to P29 displayed alternately key Press S key key To Pressure display uni refer to P30 displayed alternately key Press S key key To Pressure Ramp Up Du...

Page 28: ...ecessary see page 22 2 Press S key for 2 seconds or more then go to detail setting mode 3 To F01 by using the and keys displayed alternately 4 Press S key 5 Set the GAIN by using the and keys blink an...

Page 29: ...on become lower No Key operation LED Display 1 Deactivate the key lock if necessary see page 22 2 Press S key for 2 seconds or more then go to detail setting mode 3 To F02 by using the and keys displa...

Page 30: ...ary see page 22 2 Press S key for 2 seconds or more then go to detail setting mode 3 To F03 by using the and keys displayed alternately 4 Press S key flashes on the display 5 Press and keys for 3 seco...

Page 31: ...it by using the and keys blink and change the rightest digit Pressure display unit refer to note2 6 Press S key displayed alternately 7 Press S key for 2 seconds or more then go out from detail settin...

Page 32: ...y for 2 seconds or more then go out from detail setting mode Select the menu with or keys then jump to another item 8 Activate the key lock if necessary see page 22 Note1 The setting range of Pressure...

Page 33: ...ely 7 Press S key for 2 seconds or more then go out from detail setting mode Select the menu with or keys then jump to another item 8 Activate the key lock if necessary see page 22 Note1 The setting r...

Page 34: ...y operation LED Display 1 Deactivate the key lock if necessary see page 22 2 Press S key for 2 seconds or more then go to detail setting mode 3 To F99 by using the and keys displayed alternately 4 Pre...

Page 35: ...is different according to the pressure range and the unit of the display unit 700kPa range MPa 000 to A00 Kgf cm2 0 00 to A 00 bar 0 00 toA 00 PSI 0 to 150 kPa 0 to A00 note1 The mark is blinking the...

Page 36: ...roduct including the switch cover Use a soft dry cloth to remove stains Revision history 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld co...

Reviews: