- 30 -
Initialize
This function is the same as the function via IO-Link.
"Initialize" is a function to return all the settings that the internal control
constant are included to an initial value. Please execute "initialize" only when the error is
displayed and this product doesn't operate at all.
Please execute the "reset" function, when you want to return the pressure setting and the switch
setting to an initial value.
No
Key operation
LED Display
(1) Deactivate the key lock if necessary (see page 22).
(2) Press S-key for 2 seconds or more, then go to detail setting mode.
(3) To "F99" by using the
△
and
▽
keys.
⇔
(displayed alternately)
(4) Press S-key.
flashes on the display
)
(5)
Press
△
and S keys for 5 seconds or more.
(press S-key to (3))
is displayed
(6)
"Initialize" is executed, after 5 seconds.
(Release keys till less than 5 seconds to (4))
Turning off for 1 second
(7)
Returns to the state immediately after turning on of the power supply.
Activate the key lock if necessary (see page 22).
2021-04-20 10:43