- 25 -
Error indicating function
Error
name
LED
display
Contents of error
Countermeasure
Over range
of
input signal
Input signal exceeds the rated
value range.
Reduce input signal to within the
rated range and restart the
power supply.
System
error
Reading or writing errors
occurred in EEPROM.
Please execute "initialize (refer
to P30)" when ITV do not
operate normally after restarting
the power supply.
Please contact us, when ITV do
not operate normally after
initialize.
Reading and writing errors
occurred in memory.
Please contact us when ITV do
not operate normally after
restarting the power supply.
Solenoid
valve
error
Solenoid valve
failure.
Replace the solenoid valve.
For the replacement procedure
contact SMC.
Residual
pressure
error
Out of range error of zero clear
Please operate "zero clear"
within the range of 5%F.S..
Please operate "zero clear" after
the secondary pressure of ITV is
became to atmosphere.
2021-04-20 10:43
DI125260