Parameter index
0x41
Parameter name
Hold/Clear setting
Function
Sets the output setting when communication error occurs.
0: Exhaust completely (Clear).
1: Output pressure is maintained (Hold).
Default value: Clear
Bit
0x41
Value
Bit
0
Setting
0
Clear
1
Hold
* indicates the initial shipping value.
Parameter index
0x42
Parameter name
Gain tuning function
Function
The response time can be changed by tuning the gain. When the gain is increased,
the response time tends to be faster, but stability will be lost, which may cause
hunting (unstable pressure).
Default: Gain 9
Bit
Bit 3, 2, 1, 0
Value
Bit
3
2
1
0
Setting
0
0
0
0
Gain 0
0
0
0
1
Gain 1
0
0
1
0
Gain 2
0
0
1
1
Gain 3
0
1
0
0
Gain 4
0
1
0
1
Gain 5
0
1
1
0
Gain 6
0
1
1
1
Gain 7
1
0
0
0
Gain 8
1
0
0
1
Gain 9
1
0
1
0
Gain A
1
0
1
1
Gain B
1
1
0
0
Gain C
1
1
0
1
Gain D
1
1
1
0
Gain E
1
1
1
1
Gain F
* indicates the initial shipping value.
*
*