background image

Document  :

ITV2-OM00145 

 

 

 

 

 

 

 

 
 

PRODUCT NAME 

 

IO-Link/ELECTRO-PNEUMATIC REGULATOR 

   

 

MODEL / Series / Product Number 

 

ITV1000/2000/3000/2090-IL series 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2021-04-20 10:43

DI125260

Summary of Contents for ITV1000-IL Series

Page 1: ...Document ITV2 OM00145 PRODUCT NAME IO Link ELECTRO PNEUMATIC REGULATOR MODEL Series Product Number ITV1000 2000 3000 2090 IL series...

Page 2: ...Link Specifications P7 Setting using buttons P21 Key locking function P22 Setting of min pressure max pressure P23 Reset function P24 Error indicating function P25 Detail setting mode P26 Gain setting...

Page 3: ...equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly T...

Page 4: ...failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded...

Page 5: ...oduct is interrupted or shut off while the power is still on the internal solenoid valve will continue to operate and a humming noise will be generated Turn off the power supply when supply pressure i...

Page 6: ...ling this product and its wiring away from strong electric fields such as those of motors and power cables etc 3 Be sure to implement protective measures against load surge for inductive loads solenoi...

Page 7: ...a low ripple Turn off the power supply to remove and insert the connector Never turn the right angled type connector as it is not designed to turn Note The wire color is for when optional cable is us...

Page 8: ...he equipment construction or setting parameters When the device parameters are set and downloaded to the device using the IO Link setting tool the parameters in the downloaded device will be activated...

Page 9: ...rmal 1 Notification defined per Bit Refer to the table for Diagnostic information 4 to 10 Diagnostic information warning 0 Normal 1 Notification defined per Bit Refer to the table for Diagnostic infor...

Page 10: ...output pressure value is below the specified value 7 Pressure value over range HHH Becomes 1 when the output pressure value exceeds the specified value 8 Decline in the power supply voltage Becomes 1...

Page 11: ...t pressure 0x0000 0x0FFF Output pressure 0 100 Input data shall be entered from Bit 0 to Bit 12 of the 16 Bit process data 2 BYTE When F_1 0 F S and F_2 100 F S Ex When the output pressure is 100 the...

Page 12: ...oadStore is automatically sent to the system command as part of the block parameter sequence The customer does not need to manually issue a system command When the electro pneumatic regulator is repla...

Page 13: ...Text N IO Link Electro Pneumatic Regulator 0x0015 21 0 R Serial Number N xxxxxxxx 3 0x0016 22 0 R Hardware Revision N HW Vx y 4 0x0017 23 0 R Software Revision N FW Vx y 4 0x0018 24 0 R W Application...

Page 14: ...decimal number Command name Details 0x05 5 Param Download Store Back up of the parameter set data When the electro pneumatic regulator receives a command it starts uploading the parameter settings to...

Page 15: ...eger Value Definition of status Details 0 Normal operation 1 Maintenance is required Number of operation cycles of the built in solenoid valve have reached the set value 2 Out of spec Warning 3 Check...

Page 16: ...4 0x47 71 0 R W Maximum pressure U16 4095 Y Set setting pressure span point can be set in the range from 10 to 120 4 0x48 72 0 R Accumulated energizing time U32 0 Y Displays accumulated energizing tim...

Page 17: ...function Function The response time can be changed by tuning the gain When the gain is increased the response time tends to be faster but stability will be lost which may cause hunting unstable pressu...

Page 18: ...may occur When the sensitivity is decreased hunting will be reduced but the pressure correction will be reduced so there may be a moderate pressure instability Default value Sensitivity 0 Bit Bit 2 1...

Page 19: ...ig 2 3 The values are necessary to satisfy F_1 10 F S F2 If not the previous values are reflected in this function Default of Zero adjusting 0x0000 Bit Bit 13 It is Bit 12 up to 100 Value Relationship...

Page 20: ...0 Process data Input The set pressure output 45 when the process date input 50 Fig 3 F_1 and F_2 usage example F_1 0x0665 40 F_2 0x0999 60 Set Pressure F_1 0x0666 40 F_2 0x0800 50 60 120 100 80 40 20...

Page 21: ...ing time of the electro pneumatic regulator reached the time set with this function The default value is 0 which means no notification is output If a value is 1 or greater the notification setting is...

Page 22: ...tput pressure from this product and state of operation are changed by changing of each setting and function Each setting and function should be operated by trained and experienced operator Do not conf...

Page 23: ...y and the settings via IO Link are processed exclusively Unlocking the keys No Key operation LED Display 1 current pressure is displayed 2 Press key for 2 seconds or more is displayed 3 flashes on the...

Page 24: ...2 Minimum pressure F_1 adjusting range Maximum pressure F_2 adjusting range 0 90 100 0 50 100 0 10 120 0 50 100 100 Note 1 F_1 is adjustable in a range from 0 to 90 of the rated value DEFAULT VALUE 0...

Page 25: ...lock if necessary see page 22 2 Press the and keys simultaneously for 3 seconds or more current pressure is displayed 3 is displayed for approx 1 second 4 The settings are reset and returned to the co...

Page 26: ...normally after restarting the power supply Please contact us when ITV do not operate normally after initialize Reading and writing errors occurred in memory Please contact us when ITV do not operate...

Page 27: ...Press S key key To GAIN refer to P27 displayed alternately key key Press S key key To SENSITIVITY refer to P28 displayed alternately key Press S key key To ZERO CLEAR refer to P29 displayed alternatel...

Page 28: ...f necessary see page 22 2 Press S key for 2 seconds or more then go to detail setting mode 3 To F01 by using the and keys displayed alternately 4 Press S key 5 Set the GAIN by using the and keys blink...

Page 29: ...ection become lower No Key operation LED Display 1 Deactivate the key lock if necessary see page 22 2 Press S key for 2 seconds or more then go to detail setting mode 3 To F02 by using the and keys di...

Page 30: ...ary see page 22 2 Press S key for 2 seconds or more then go to detail setting mode 3 To F03 by using the and keys displayed alternately 4 Press S key flashes on the display 5 Press and keys for 3 seco...

Page 31: ...e switch setting to an initial value No Key operation LED Display 1 Deactivate the key lock if necessary see page 22 2 Press S key for 2 seconds or more then go to detail setting mode 3 To F99 by usin...

Page 32: ...yed as A00 kPa and it shows 1000 kPa note3 When the display exceeds the lower bound value is displayed note4 When the display exceeds the upper bound value is displayed Maintenance Before performing m...