-17-
No.PS
※※
-OMV0004-C
■
Wiring
•Connections should be made with the power supply turned off.
•Use a separate route for the product wiring and any power or high voltage wiring. Otherwise, malfunction
may result due to noise.
•If a commercially available switching power supply is used, be sure to ground the frame ground (FG)
terminal. If the switching power supply is connected, switching noise will be superimposed and it will not be
able to meet the product specifications. In that case, insert a noise filter such as a line noise filter/ferrite
between the switching power supplies or change the switching power supply to the series power supply.
○How to use connector
•Align the cable connector key groove with the product connector key to insert and rotate the knurled part
of the connector.
•Connect the wires of the lead wire with M12 connector as shown below.
M12 connector (Port Class A)
Used as switch output device
No.
Name
Lead wire colour
Function
1
DC(+)
Brown
12 to 24 VDC
2
OUT2
White
Switch output 2
3
DC(-)
Blue
0 V
4
OUT1
Black
Switch output 1
Used as IO-Link device
No.
Name
Lead wire colour
Function
1
L+
Brown
18 to 30 VDC
2
DO
White
Switch output 2
3
L-
Blue
0 V
4
C/Q
Black
Communication data (IO-Link)/Switch output 1 (SIO)