-69-
No.PS
※※
-OMV0004-C
●
Product individual parameters (continued)
Index
Sub
index
Access
1
Parameter
Data
type
2
Initial
value
Data
storage
3
Set value
Remarks
dec
hex
1100 0x044C
0
R/W
L
o
we
r l
e
ve
l s
cr
e
e
n
Setting of lower level
screen
U8
0
Y
0: Std
1: dUAL (2 value display)
2: o1Lv (OUT1 level bar)
3: o2Lv (OUT2 level bar)
4: LinE (Line name)
5: oFF (No display)
1101 0x044D
0
R/W
During Std setting
Selection of display
item
U8
0
Y
Refer to Table
"selection of display
items during std
setting".
1102 0x044E
0
R/W
During 2 value setting
Selection of display
item
Left side
U8
0
Y
Refer to Table
"Selection of display
items during 2 value
setting".
1103 0x044F
0
R/W
During 2 value setting
Selection of display
item
Right side
U8
1
Y
1820 0x071C
0
R/W
Line name
1st letter
U8
0
Y
Refer to Figure "1st
letter (11seg) of Line
name communication
data".
1821 0x071D
0
R/W
Line name
2nd letter
U8
0
Y
Refer to Figure "1nd to
4th letter (7seg) of
Line name
communication data".
1822 0x071E
0
R/W
Line name
3rd letter
U8
0
Y
1823 0x071F
0
R/W
Line name
4th letter
U8
0
Y
1824 0x0720
0
R/W
Line name
Left side bot
U8
0
Y
0: OFF (dot OFF)
1: ON (dot ON)
1825 0x0721
0
R/W
Line name
Centre bot
U8
0
Y
1826 0x0722
0
R/W
Line name
Right side bot
U8
0
Y
1110 0x0456
0
R/W
drE
(Selection of display value
resolution)
U8
0
Y
0: Normal resolution
1: Lower resolution
(1/10)
Setting of display value resolution
1140 0x0474
0
R/W
Cut
(Zero-cut)
U8
0
Y
0 ~ 10
Display value around 0 is displayed as 0.
1.0% increments
1800 0x0708
0
R/W
Eco
(Economy mode)
U8
0
Y
0: oFF
1: n
Setting of power saving mode
1810 0x0712
0
R/W
S
e
cu
ri
ty
co
d
e
Pin
(Use or unuse)
U8
0
Y
0: Unused
1: Used
Setting of use or unuse of the security
code
1811 0x0713
0
R/W
NPin
(Security code)
U16
0
Y
0 ~ 999
Setting of security code
2000 0x07D0
0
R
M
e
a
su
re
m
e
n
t
re
lat
e
d
Process data
Conversion formula
Inclination a
F32
N
Refer to table "Inclination and
intercept to the unit specification".
(Page
63
)
2001 0x07D1
0
R
Process data
Conversion formula
Intercept b
F32
N
2002 0x07D2
0
R
Peak value
U16
0
N
Refer to process data on page
61
to
63
.
2003 0x07D3
0
R
Bottom value
U16
0
N
2004 0X07D4
0
R
Di
a
g
n
o
stic
inf
o
rm
a
tio
n
Number of
pressurizing errors
U16
0
N
0 ~ 1000
1: "R" means Read and "W" means Write.
2: Refer to the table below for the symbol.
Symbol
Data type
(IO-Link standard)
Data length
Bit [byte]
Description
U8
UIntegerT
8 [1]
Unsigned integer
U16
16 [2]
S16
IntegerT
16 [2]
Signed integer
F32
Float32T
32 [4]
Floating point number
3: "Y" indicates that the parameter setting data is saved to the master, and "N" indicates that the parameter is not saved.