-44-
No.PS
※※
-OMV0004-C
■
[F11] Display resolution setting
This function is to change the pressure display resolution.
The flicker of the display can be reduced.
<Operation>
Press the UP or DOWN button in function selection mode to display [F11].
Press the SET button.
Move on to display resolution setting.
Display resolution setting
Press the UP or DOWN button to select the display resolution.
Press the SET button to set.
Return to function selection mode.
[F11] Display resolution setting completed
: It may not be possible to change the resolution depending on the unit of pressure selected.
The units that allow display resolution to be selected are [MPa], [kPa], [kgf/cm
2
], [bar] and [psi].
(The units [kgf/cm
2
], [bar] and [psi] can only be set when using a product with units selection function.)
Page
27
[F 0] Display units, switch output specifications and diagnostic information selection function