background image

 

- 12 - 

 

 

 

 

Caution

 

Environment

 

 

(1)Do  not  use  the  product  in  an  environment  where  the  product  is  directly   

exposed  to  corrosive  gases,  chemicals,  salt  water  or  steam. 

(2)Do  not  mount  the  product  in  a  location  where  it  is  subject  to  strong  vibrations

  and/or  shocks. 

(3)Use  this  vacuum  regulator  in  a  location  free  from  dirt  since  this  product

 

 

sucks  atmosphere  all  the  time. 

(4)When  the  product  is  directly  exposed  to  sunlight,  provide  a  protective  cover. 
(5)When heat source is around the product, shut off radiant heat. 
 
 

 

Caution

 

Vacuum Source

 

 

(1)  This  vacuum  regulator  does  not  control  pressure  by  connecting  with  the   

exhaust  side  of  the  vacuum  pump. 

       

   

(2)Note that ejector should not be used as ”vacuum source” since its flow rate is less 

than this vacuum regulator. 

 

 

Caution

 

Air

 

 

(1) Contact SMC when using the product in applications other than 

                      Compressed air. 

(2)  Do  not  use  air  containing  chemicals,  synthetic  oils  with  organic  solvents, 
      Salinity  and  corrosive  gases. 
   
 

 

 

Caution

 

Operation

 

 

(1) Connect vacuum pump to the port indicated by “VAC”(shown in upper 

                    Right of the port). 
                (2) Pressure changes ”atmospheric pressure→vacuum pressure” by turning 
                    the handle clockwise and “vacuum pressure→atmospheric pressure” by 
                    turning the handle counterclockwise. 

(3)Pressure cannot be controlled if the air intake hole (hole on the side of the 

 

body) is blocked. Do not block the air intake hole by hand or with an object   
during pressure adjustment. 

(4)To lock the handle after pressure setting, push the handle until orange 

                    Mark below is hidden and it clicks. To unlock the handle, pull the handle 
                    Until the orange make is seen and it clicks. 
                (5)Maximum settable vacuum pressure is affected by the atmospheric pressure where 

the  vacuum  regulator  is  used.  Atmospheric  pressure  varies  depending  on  the 
altitude and weather. Actual maximum settable vacuum pressure may not reach the 
value in the specification. 

                (6)When vacuum pump capacity is relatively small or piping ID is small, large 
                    fluctuation of set pressure (variation range in pressure when flowing from 
                    zero) may be the result. In this case, change the vacuum pump or piping 

Summary of Contents for IRV10

Page 1: ...No DIK 45700 OM002 A PRODUCT NAME Vacuum regulator MODEL Series...

Page 2: ...1 Table of Contents Safety Instructions 2 3 Introduction 4 Specifications 4 Construction and Operating Principle 5 How to Order 6 7 Specific Product Precautions 8 13 Warranty 14...

Page 3: ...t failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assem...

Page 4: ...of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from th...

Page 5: ...D 6 8 1 4 5 16 6 8 10 1 4 5 16 3 8 SET side tubing O D Weight No accessories Standard connections 135g IRV10 C08 250g IRV20 C10 Single sided connections 125g IRV10A C08 250g IRV20A C10 Note1 This var...

Page 6: ...of this diaphragm is pushed up so that main valve c loses and atmosphere suction valve opens Atmosphere flows in SET Pressure and becomes SET Pressure when compression force of set Spring balances wit...

Page 7: ...t size symbol Port size IRV10 IRV20 C06 mm 6 C08 8 C10 10 N07 inch 1 4 N09 5 16 N11 3 8 Accessories1 Accessory is included in the same container Nil No accessory B With Bracket L With Bottom Bracket B...

Page 8: ...function ZB PNP open collector 2 outputs Copy function One touch fitting Nil Straight L Elbow Connection port size symbol Port size IRV10A IRV20A C06 mm 6 C08 8 C10 10 N07 inch 1 4 N09 5 16 N11 3 8 A...

Page 9: ...danger of system is expected when vacuum regulator fails provide the system with a safety circuit to avoid such a danger 3 Keep the specified tightening torque for mounting Excessive torque can damag...

Page 10: ...iece Note For the summarized piping specification only 1 clip is provided and no plug nut is provided Pressure gauge Pressure switch Gauge nut Plug nut Clip 1 2 Mounting of pressure gauge or pressure...

Page 11: ...ing remove the clip with flat blade driver Then insert one touch fitting until it contact to the end and insert the clip to its original position Note1 Before replacement ensure that VAC SET pressure...

Page 12: ...11 How to pull out the clip Set the driver tip to the slope of the place where the clip inserted lift the clip by moving the driver slowly Mounting of fitting assembly Fitting assembly Clip Clip...

Page 13: ...ases Caution Operation 1 Connect vacuum pump to the port indicated by VAC shown in upper Right of the port 2 Pressure changes atmospheric pressure vacuum pressure by turning the handle clockwise and v...

Page 14: ...andle 10 If the directional control valve solenoid valve mechanical valve etc is mounted and switched ON OFF repeatedly for a long time the set pressure may vary If the setting value varies adjust wit...

Page 15: ...product does not have any defects in components materials or assembly c We guarantee that the product complies with the outline dimensions provided d The following situations are out of scope of this...

Page 16: ...Revision A How to Order display content correction etc URL http www smcworld com 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 Japan Tel 03 5207 8271 Fax 03 5298 5361 2021 SMC Corporation All Rights Rese...

Reviews: