Safety Instructions

 

 

These safety instructions are intended to prevent hazardous situations and/or equipment damage.

 

These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.”

 

They  are  all  important  notes  for  safety  and  must  be  followed  in  addition  to  International  Standards 
(ISO/IEC)*1) , and other safety regulations.

 

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.

 

   

ISO 4413: Hydraulic fluid power -- General rules relating to systems.

 

   

IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements)

 

   

ISO 10218: Manipulating industrial robots -Safety.

                                                                                 

 

  etc.

 

     

 
 

Caution

 

Caution

 indicates a hazard with a low level of risk which, if not avoided, could result 

in minor or moderate injury.

 

 
 

Warning

 

Warning

 

indicates a hazard with a medium level of risk which, if not avoided, could 

result in death or serious injury.

 

 
 

Danger

 

Danger

 

indicates a hazard with a high level of risk which, if not avoided, will result 

in death or serious injury.

 

 

Warning

 

1. The compatibility of the product is the responsibility of the person who designs the equipment or 

decides its specifications.

 

Since  the  product  specified  here  is  used  under  various  operating  conditions,  its  compatibility  with  specific 
equipment must be decided by the person who designs the equipment or decides its specifications based on 
necessary analysis and test results.   
The expected performance and safety assurance of the equipment will be the responsibility of the person who 
has determined its compatibility with the product.   
This  person  should  also  continuously  review  all  specifications  of  the  product  referring  to  its  latest  catalog 
information, with a view to giving due consideration to any possibility of equipment failure when configuring the 
equipment.

 

2. Only personnel with appropriate training should operate machinery and equipment.

 

The product specified here may become unsafe if handled incorrectly.

 

The  assembly,  operation  and  maintenance  of  machines  or  equipment  including  our  products  must  be 
performed by an operator who is appropriately trained and experienced.

 

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.

 

1.The inspection and maintenance of machinery/equipment should only be performed after measures to   

prevent falling or runaway of the driven objects have been confirmed.

 

2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented 
    and the power from any appropriate source is cut, and read and understand the specific product precautions 
    of all relevant products carefully.

 

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

 

4. Contact SMC beforehand and take special consideration of safety measures if the product is to 

be used in any of the following conditions.

 

1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to 
    direct sunlight.

 

2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, 

  vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and 
  beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or 
  other applications unsuitable for the standard specifications described in the product catalog.

 

3. An application which could have negative effects on people, property, or animals requiring special safety   

analysis.

 

4.Use  in  an interlock circuit,  which  requires the  provision  of  double  interlock  for possible failure  by  using  a 

mechanical protective function, and periodical checks to confirm proper operation. 

 

 

Summary of Contents for IRV10

Page 1: ...No DIK 45700 OM002 A PRODUCT NAME Vacuum regulator MODEL Series...

Page 2: ...1 Table of Contents Safety Instructions 2 3 Introduction 4 Specifications 4 Construction and Operating Principle 5 How to Order 6 7 Specific Product Precautions 8 13 Warranty 14...

Page 3: ...t failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assem...

Page 4: ...of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from th...

Page 5: ...D 6 8 1 4 5 16 6 8 10 1 4 5 16 3 8 SET side tubing O D Weight No accessories Standard connections 135g IRV10 C08 250g IRV20 C10 Single sided connections 125g IRV10A C08 250g IRV20A C10 Note1 This var...

Page 6: ...of this diaphragm is pushed up so that main valve c loses and atmosphere suction valve opens Atmosphere flows in SET Pressure and becomes SET Pressure when compression force of set Spring balances wit...

Page 7: ...t size symbol Port size IRV10 IRV20 C06 mm 6 C08 8 C10 10 N07 inch 1 4 N09 5 16 N11 3 8 Accessories1 Accessory is included in the same container Nil No accessory B With Bracket L With Bottom Bracket B...

Page 8: ...function ZB PNP open collector 2 outputs Copy function One touch fitting Nil Straight L Elbow Connection port size symbol Port size IRV10A IRV20A C06 mm 6 C08 8 C10 10 N07 inch 1 4 N09 5 16 N11 3 8 A...

Page 9: ...danger of system is expected when vacuum regulator fails provide the system with a safety circuit to avoid such a danger 3 Keep the specified tightening torque for mounting Excessive torque can damag...

Page 10: ...iece Note For the summarized piping specification only 1 clip is provided and no plug nut is provided Pressure gauge Pressure switch Gauge nut Plug nut Clip 1 2 Mounting of pressure gauge or pressure...

Page 11: ...ing remove the clip with flat blade driver Then insert one touch fitting until it contact to the end and insert the clip to its original position Note1 Before replacement ensure that VAC SET pressure...

Page 12: ...11 How to pull out the clip Set the driver tip to the slope of the place where the clip inserted lift the clip by moving the driver slowly Mounting of fitting assembly Fitting assembly Clip Clip...

Page 13: ...ases Caution Operation 1 Connect vacuum pump to the port indicated by VAC shown in upper Right of the port 2 Pressure changes atmospheric pressure vacuum pressure by turning the handle clockwise and v...

Page 14: ...andle 10 If the directional control valve solenoid valve mechanical valve etc is mounted and switched ON OFF repeatedly for a long time the set pressure may vary If the setting value varies adjust wit...

Page 15: ...product does not have any defects in components materials or assembly c We guarantee that the product complies with the outline dimensions provided d The following situations are out of scope of this...

Page 16: ...Revision A How to Order display content correction etc URL http www smcworld com 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 Japan Tel 03 5207 8271 Fax 03 5298 5361 2021 SMC Corporation All Rights Rese...

Reviews: