background image

 

Air Dryer

                                                                                       

2 Transportation / Installation

 

 

 

Specification of power cable 

Prepare following power cable. 

 

Power cable: 1.25mm

2

(16AWG), External diameter: about 8 ~ 12mm 

IDU22E 

75E-30 (3 phase power supply) …4 cores (including grounding) 

Additional length of about 0.2m is needed to wire inside of the product. 

Length of the power cable 

The length of the power cable should extend less than 30m from the product. 

Connecting to the power supply 

Connect the power cable and the earth to the terminal block. M3 screw is used for the connection part. Make sure 

to use round crimped terminal. 

Applicable crimped terminal: 1.25-3 (Width: 6.5mm and below) 
 

Wiring procedure 

Remove the front panel. 

Insert the cord through the rubber grommet and connect it to the terminal block (refer to the label on the terminal 

block).

 

M3 screw tightening torque: 0.6~1Nm 

 

During wiring work, do not touch other sections except terminal block. 

Attach the front panel as it were. 

 

2 - 3  

Cautions about Reinstallation 

 

Caution 

No one but someone who has enough knowledge about the product and incidental 
devices should reinstall in another place. And following instructions must be executed. 

If you move the product and reinstall it into another place after some operations (including trial running), 
instructions that are not only following ones but also all of those in the chapter 2 should be followed. 

 
Disassembly of the power cable 

Cut off the power source when you disassemble the power cable. 

Warning 

No one but qualified personnel should do the electric wiring. 
Cut off the power supply for safety before the wiring. Do not work under energized 
condition. 

Disassembly of the air piping 

Warning 

No one but qualified personnel should do the air piping. 

Separate the compressor from the product for safety before removing the iping. Do not 

remove any piping when there is remaining compressed air pressure inside of it.

 

Remove the s

eal tape completely after detaching the piping. Remained tape will cau

se imperfect 

cooling and failure by entering into the body of the product.  

 

Residual compressed air pressure release procedure 

Even while the dryer is removed, only when compressed air is 
needed, open the bypass piping valve. 

Close the compressed air inlet and outlet valve. 

Make sure the ball valve located next to the auto drain opened. 

Case Assembly

The ramainder depressure cock.

It opens when turning in the

    drection og the arrow of figure.

Open the auto drain residual pressure release valve 

to release air pressure inside the product. Refer to

 

 

the figure at right. 

Summary of Contents for IDU11E-23-C,K,L,R,T,V

Page 1: ...mber 2010 Operation Manual PRODUCT NAME Refrigerated Air Dryer MODEL Series IDU22E 30 IDU37E 30 IDU55E 30 IDU75E 30 Please read this manual prior of using the air dryer Keep the manual readily availab...

Page 2: ...nstallation and operation of the product Only those who have thorough understanding of the fundamental operating procedure or have basic knowledge and skills of handling industrial product for the ins...

Page 3: ...portation Installation 2 1 Transportation 2 1 2 2 Installation 2 2 2 2 1 Location 2 2 2 2 2 Anchorage 2 2 2 2 3 Air piping 2 2 2 2 4 Drain Tube 2 3 2 2 5 Electric wiring 2 3 2 3 Cautions about reinsta...

Page 4: ...or maintemance representative should do daily operations on their own head Operators and maintemance representatives should take the safety of working place and work environment into account It is nec...

Page 5: ...s of life if someone handle wrongly during operation or maintenance and did not follow the procedure to avoid danger Caution Statements with the Danger sign explain about possibilities that can result...

Page 6: ...ter 5 Troubleshooting Ask repair and maintenance Warning The product should not be operated in the event of any problems When the product gets out of order shutdown it immediatery and contact our serv...

Page 7: ...esulting from contact with them What is more there is also the danger of burn injury due to remaining heat after the power supply is cut Therefore wait until the temperature of hot parts become 50 o C...

Page 8: ...g labels Confirm the positions of danger warning labels Front Front IDU22E 37E IDU55E 75E WARNING 1 Remove panels for maintenance only 2 Never insert anything into product to ensure safety 3 Cut power...

Page 9: ...e about the product and incidental device should do the collection of the refrigerant No one but service person or qualified person should remove the cover panel of the product The quantity and the so...

Page 10: ...URRENT Running current REFRIGERANT Type of refrigerant amount WEIGHT Weight MAX PRESS Maximum operating pressure SERIAL No Serial No MANUFACTURING DATE Manufacturing Date MADE IN Country of manufactur...

Page 11: ...and experience about the product and incidental devices should do the collection of the refrigerant No one but service person or qualified person shoud remove the cover panel of the product The quant...

Page 12: ...3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products Compliance Requirements 1 The use of SMC products...

Page 13: ...elay L1 L2 L3 PE Switch with Lamp ON OFF Switch The lamp is continuously ON during normal operation Use it for ON OFF operations Evaporation thermometer Evaporating Temp Indicates the temperature of r...

Page 14: ...tions Parts Fixing Screw for Front Panel Another one is on the right side Left Side Ventilation Grille Inlet Breathe in cooling air from this grill Do not bung up with wall and so on Rubber Grommet Po...

Page 15: ...n Use it for ON OFF operations Evaporation thermometer Evaporating Temp Indicates the temperature of refrigerant of low pressure side During normal driving it indicates in the green zone Drain Tube Di...

Page 16: ...tions Parts Fixing Screw for Front Panel Another one is on the right side Left Side Ventilation Grille Inlet Breathe in cooling air from this grill Do not bung up with wall and so on Rubber Grommet Po...

Page 17: ...om the base surface with careful attention to prevent falling sideways and drop Do not bring the product lying sideways If you lay it sideways it will be broken Do not hang up the product Do not trans...

Page 18: ...oo much force and weight are put on the body of the product that causes it to deform Circumstances where enough spaces cannot be taken to do maintenance in the plant where the product is operated Spac...

Page 19: ...air drain will be discharged periodically Fix the outlet end of the tube so as not to swing during discharge Prevent the drain tube from riser piping Prevent the drain tube from being folded or flatt...

Page 20: ...ct and reinstall it into another place after some operations including trial running instructions that are not only following ones but also all of those in the chapter 2 should be followed Disassembly...

Page 21: ...to the auto drain opened 3 2 Operation Start operation according to the procedure below Turn on the breaker of the main power supply Then turn on the Switch with Lamp The lamp will light up Few minut...

Page 22: ...for at least 3 minutes before restarting air dryer after it has been shut down Failure to do this may cause safety devices to trip due to over load If it is not possible to restart refer to Chapter 5...

Page 23: ...ow nozzle once a month Caution During air blowing put on protective glass and mask to prevent dusts from coming into hroat or eyes t 4 2 2 Service parts It is recommended to replace the following part...

Page 24: ...ation is shut down after switching off the air dryer s illuminated light there are also charging lines When working on the charged sections be sure to switch off the earth leakage breaker installed be...

Page 25: ...k button and slowly pull down the case assembly vertically to remove it Pour solution of neutral detergent into the case assembly and shake it well to clean Check the case O ring for damage such as sc...

Page 26: ...et the thermal relay and high pressure switch Temperature of the compressed air is too high Improve the ventilation system around air compressor or make ambient temperature around air compressor low t...

Page 27: ...pressor low to lower the temperature of discharge from compressor Reduce the temperature of the compressed air by installing an additional after cooler after air dryer Bypass valve of air dryer is not...

Page 28: ...e found on the power supply terminal base Confirm that a green indication does not appear at an indication window of thermal relay If the green indication appears there are other possible causes and c...

Page 29: ...r consumption Note 2 W 1100 1450 1530 2000 2200 2850 Electrical Specification Circuit Breaker Note 3 A 10 Condenser Air cooling Refrigerant R407C HFC Refrigerant Charge g 470 10 830 10 550 10 745 10 A...

Page 30: ...ET DRAFT 13 4x POWER SUPPLY ENTRY 9 11 OPPOSITON WIRE F J H C G B D E M A P K L 2 N 1 THERMOMETER VENTILATION BLOCK AIR OUTLET WITH LAMP measure mm Model Port size A B C D E F G H J K L M N P IDU22E R...

Page 31: ...30 3 phase AC200V SYMBOL DESCRIPTION CM Compressor Motor FM1 FM2 Fan Motor For Condensor MC1 MC2 Magnetic Contactor PRS PRS1 Pressure Switch PRS2 High Pressure Switch ILS Switch with Lamp THR Thermal...

Page 32: ...moisture Finally it exchanges its heat with hot and humid air which comes in the air dryer and it goes out from the air dryer as warm and dry air Refrigerant Circuit The fluorocarbon charged in the re...