Page 1: ...Manual 1 2 NCH840BK00 840 Count Compressor Cigar Humidor OWNERS MANUAL Read and save these instructions...

Page 2: ...Installation 7 Operating Instructions 9 Cleaning Maintenance 15 Troubleshooting 16 Limited Manufacturer s Warranty 18 MODEL NO NCH840BK00 CAPACITY 4 Cu Ft VOLTAGE 120V CURRENT 1 4A FREQUENCY 60Hz TEMP...

Page 3: ...of Purchase Serial Number Model Number Register Your NewAir Product Online Today Take advantage of all the benefits product registration has to offer Service and Support Diagnose troubleshooting and s...

Page 4: ...vapors and liquids in the vicinity of this appliance The fumes can create a fire hazard or explosion This appliance is not intended for food storage This appliance is not intended for use by people i...

Page 5: ...with a flammable propellant in this appliance When positioning the appliance ensure the supply cord is not trapped or damaged Do not locate multiple portable socket outlets or portable power supplies...

Page 6: ...newair com 6 PARTS LIST...

Page 7: ...electrical outlet Placed away from the microwave oven Certain microwave ovens do not have a wave interference shield When placed within 3 feet vicinity of a microwave over the cigar humidor s operati...

Page 8: ...should be installed in a suitable place where the compressor will not be subject to physical contact Leveling your cigar humidor cigar humidor must be leveled BEFORE loading your cigar Your cigar humi...

Page 9: ...ilize IMPORTANT If the unit is unplugged power is lost or turned off wait 3 to 5 minutes before restarting the unit The cigar humidor will not start if you attempt to restart before this time delay Op...

Page 10: ...T button Press the LED LIGHT button and the light turns on Press the button again and the light turns off TEMPERATURE display window Displays internal temperature HUMIDITY display window Displays inte...

Page 11: ...cigar humidor within a 2 5 F range but the actual temperature of the cigar will only fluctuate 0 5 F to 1 F NOTES The cigar humidor temperature control function can keep the best temperature for ciga...

Page 12: ...void opening or removing any parts of the humidification system without technical assistance Avoid filling with unfiltered water since it may cause harm to cigar quality or taste Check the water filli...

Page 13: ...ccurs the defrost function will melt the frost and collect it in a tray located at the back of the cigar humidor next to the compressor where the compressor s heat will evaporate the water and recycle...

Page 14: ...rawer down 3 Pull the drawer off the sliding roller rack and out of the cigarhumidor 1 Take out handle from cabinet then take out 4pcs 4 35 screws from accessory bag 2 Pull open door seal from the sid...

Page 15: ...warm water and a baking soda solution The solution should be about 2 tablespoons of baking soda to a quart of water The outside of the cigar humidor should be cleaned with mild detergent and warm wate...

Page 16: ...ed by a qualified electrician WARNING Any intervention performed by a non authorized technician will lead to the warranty being void In the event of a power interruption all previous temperature setti...

Page 17: ...eal properly Replace the seal on the door Replacements can be acquired from the NewAir customer supportdepartment The humidor does not have sufficient clearance Make sure there is at least 5 inches cl...

Page 18: ...e of indoor fan Contact a qualified technician for repairing Left window shows LL Low Temperature Ambient temperature is too low Avoid using at ambient temperature below 32 degrees Farenheit Refrigera...

Page 19: ...ive household wiring or inadequate fuses Accident alteration misuse or abuse of the appliance such as using non approved accessories inadequate air circulation in the room or abnormal operating condit...