2 Transportation / Installation
2 - 2
Installation
2 - 2 - 1
Location
The product should not be used or stored in the following conditions: Those conditions will cause
not only malfunction but also failures.
•
Environment where the product is exposed to
rainwater, moisture, salt water or oil.
•
Locations where the product is exposed to dust
or particles
•
Locations where the product is exposed to
flammable, combustible or explosive fumes.
•
Locations where the product is exposed to
corrosive gas or solvent.
•
Locations where the product is exposed to
direct sunlight or radiated heat.
•
Locations where ambient temperature is
beyond following range:
•
On-stream: 2 to 40oC
•
Storage: 0 to 50oC (when there is no drain
water inside of the piping)
•
Locations where temperature changes rapidly.
•
Locations where strong electromagnetic noise
is generated.
•
Circumstances where static electricity is
produced or discharged through the body of the
product
•
Locations where strong high frequency shock
wave is generated
•
Locations where danger of thunder is apparent.
•
Locations where loading on vehicles, marine
vessels, and so on
•
Locations where altitude is higher than 2,000
meters
•
Circumstances where strong vibration or impact
are transmitted.
•
Circumstances where
too much force and weight
are put on the body of the product that causes it to
deform.
•
Circumstances where not enough clearance
spaces to do maintenance
•
Spaces needed for maintenance
•
Front :
600mm
•
Rear :
600mm
•
Top : 600mm
•
ight : 600mm
•
Left : 600mm
•
Locations where ventilation grille of the product can
be blocked.
•
Locations where the dryer could intake warm air (for
example from a compressor or other dryers).
2 - 2 - 2
Anchorage
•
The air dryer should be installed on a vibration-free, stable, horizontal flat surface.
•
Refer to “Chapter6 6-2 Dimensions” for the dimensions.
•
IDU8E~15E should be bolted by anchor bolts to prevent falling. We recommend the anchor bolt sets that
we are selling separately as accessories.
2 - 2 - 3
Air
piping
•
Connection to the inlet and outlet of compressed air should be made removable by using union and so on.
•
Pressing the hexagonal fitting with screw wrench and so on, connect the air piping fittings to the body.
•
When mounting any part such as an air filter on the fitting at the compressed air inlet or outlet port, support the
part to prevent excessive force from being applied to the product.
•
Be careful not to let the vibration of the air compressor transmit.
2
-
2