![background image](http://html1.mh-extra.com/html/smc-networks/idf11e-10-a/idf11e-10-a_operation-manual_1299704035.webp)
IDX-OM-W010
Air Dryer
6 References
6-1 Specifications
6 - 1
IDF Series
6 References
6-1 Specifications
Model
Specification
IDF1E
IDF2E
IDF3E
IDF4E
IDF6E
IDF8E IDF11E
IDF15E1
Rated Cond
ition
Air Flow Rate
m
3
/min (ANR)(Note 1)
50Hz 0.1 0.2 0.32 0.52 0.75 1.22 1.65 2.8
60Hz 0.12 0.235 0.37 0.57 0.82 1.32 1.82 3.1
Operating Pressure
0.7MPa
Inlet Air Temperature
35
o
C
Ambient Temperature
32
o
C
Pressurized Dew Point
10
o
C
Operating
Range
Working Fluid
Compressed Air
Inlet Air Temperature
5 ~ 50
o
C
Inlet Air Pressure
0.15 ~ 1.0MPa
Ambient Temperature
2 ~ 40
o
C(Relative Humidity of 85% or less)
E
lec
tr
ic
al
S
p
eci
fic
a
tio
n
Power source
100VAC(50/60Hz)
Single phase AC100/100 , 110V
[
Voltage fluctuations
±
10%
]
200VAC(50/60Hz)
Single phase AC200/200 , 220V
[
Voltage fluctuations
±
10%
]
Operating urrent
(Note 2) A
100VAC(50/60Hz) 2.4/2.5
2.4/2.5
2.4/2.5
2.4/2.5
2.4/2.5
3.0/3.1 5.7/5.7
4.3/4.6
200VAC(50/60Hz)
1.2/1.3
1.2/1.3
1.2/1.3
1.5/1.5
3.4/3.0
3.4/3.1
Power
consumption
(Note 2) W
100VAC,200VAC
(50/60Hz)
180/202
180/202
180/202
180/202
180/202
208/236 385/440
420/480
Circuit Breaker
(Note 3)
100VAC 10A
200VAC 5A
10A
Condenser
Plate fin tube type with forced air cooling
Refrigerant R134a
(HFC)
Refrigerant Charge(AC100V/200V) g
70
±
5 115
±
5 150
±
5 180
±
5 200
±
5 250
±
5 260
±
5 350
±
10
Drain Connection
Rc3/8
Rc1/2
Rc3/4
Rc1
Drain Connection
10mm
Coating Color
Panel: Urbanwhite 1
Base: Urbangray 2
Weight
kg 16 17 18 22 23 27 28 46
Applicable Compressor(Standard) kW
0.75
1.5
2.2
3.7
5.5
7.5
11
15
Note1: The data for m
3
/min (ANR) is referring to the conditions of 20
°
C, 1atm. pressure & relative humidity of
65%.
Note 2: The value is that of under specified condition.
Note 3: Install GFCI breaker with sensivity of
30mA.
Note 4: When short period power shortage (including instantly recovered shortage) is recovered, it may take a longer starting
period than usual starting or may not start due to the protective devices.