HRX-MM-L012
Chapter 4 Service Procedure
HRGC Series
4.3 Replacement procedure
4-17
4.3.3
Replacement of pump mechanical seal
(< HRGC001-
∗
-T,HRGC002-
∗
-T,HRGC005-
∗
)
Table 4-9 Part number of service parts (mechanical seal)
Part number
HRG-S0211
Removal
1.
Remove the body. (Hexagon socket head bolt x 3)
Place the drain pan under the body and drain water from the pump.
2.
Remove the collar. (Set screw x 2)
[Key point]
There is a danger of parts popping out.
3.
Remove the impeller and spring.
[Key point]
If the impeller gets stuck and cannot be removed, screw two screws of M6 x
50mm or larger into the two thread holes of the impeller to pull out the
impeller.
4.
Remove the mechanical seal, O-ring and cover all in one.
[Key point]
If the cover cannot be removed, insert the blade of the spanner/wrench
between the cover and motor and bring it up.
5.
Remove the deflector rubber.
Summary of Contents for HRGC001-A Series
Page 6: ...HRX MM L012 Contents HRGC Series Contents 4 ...
Page 15: ...HRX MM L012 Chapter 1 Safety Instructions HRGC Series 1 7 Material Safety Data Sheet MSDS 1 9 ...
Page 16: ......
Page 28: ...HRX MM L012 Chapter 3 Error Display and Remedy 3 4 Other Errors HRGC Series 3 8 ...
Page 74: ...HRX MM L012 Chapter 4 Service Procedure 4 3 Replacement procedure HRGC Series 4 46 ...
Page 92: ...HRX MM L012 Chapter 5 Service Parts List 5 3 Illustration of service parts HRGC Series 5 18 ...