-31-
No.EX
※※
-OMX1001
■
Web server function
The SI unit has a Web server function which allows checking the information of the unit information from a
PC Web browser during maintenance, or checking of I/O monitor or forced output of ON/OFF of the valve.
•Connection of SI unit and PC
Connect SI unit and PC to the same Ethernet network, then start the Web browser on the PC.
The SI unit can be connected to the Web server by inputting SI unit IP address to the Web browser address
bar.
NOTE
Set the same significant 3 octets of PC IP address as SI unit IP address.
Set the PC subnet mask to "255.255.255.0".
Ex. 1 SI unit: 192.168.0.100 PC: 192.168.0.1 OK: Correct IP address setting
Ex. 2 SI unit: 192.168.0.100 PC: 192.168.3.1 NG: Incorrect IP address setting